Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
02/14/2025 | Site Engineering Complex | REQUIRES RESUBMIT | TE-FPU-0924-00300 2549 E KLEINDALE RD Comments for Site Engineering are as follows: 1. The vents shown in the pictures of the shed appear to be over 1ft from the adjacent grade. - “ASCE 24 Section 2.7.3. Specifies the following for the installation of openings: • At least two openings in at least two walls of each enclosed area • The bottom of each opening not more than 1 foot above the higher of the final interior grade or floor and the finished exterior grade immediately under each opening.” - NFIP Technical Bulletin 1 / March 2020 Ryan Insalaco – ryan.insalaco@tucsonaz.gov |