Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Number: TE-FPU-0924-00300
Parcel: 112030250

Review Status: Requires Resubmit

Review Details: FLOODPLAIN USE REVIEW v.1

Permit Number - TE-FPU-0924-00300
Review Name: FLOODPLAIN USE REVIEW v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
02/14/2025 Site Engineering Complex REQUIRES RESUBMIT TE-FPU-0924-00300
2549 E KLEINDALE RD

Comments for Site Engineering are as follows:
1. The vents shown in the pictures of the shed appear to be over 1ft from the adjacent grade.
- “ASCE 24 Section 2.7.3. Specifies the following for the installation of openings: • At least two openings in at least two walls of each enclosed area • The bottom of each opening not more than 1 foot above the higher of the final interior grade or floor and the finished exterior grade immediately under each opening.” - NFIP Technical Bulletin 1 / March 2020
Ryan Insalaco – ryan.insalaco@tucsonaz.gov