09/18/2023 Site Engineering REQUIRES RESUBMIT 1. The proposal of solar panels on the shed constitutes a substantial improvement to the structure per FEMA's substantial improvement regulations (https://www.fema.gov/sites/default/files/documents/fema_nfip_substantial-improvement-substantial-damage-desk-reference.pdf). In order for the floodplain permit to be approved, there are two options. 1: Certify that the shed is compliant with floodplain standards (is elevated 1 foot above the base flood elevation) with a elevation certificate filled out by a registered land surveyor or 2: move the panels from the shed to the main house, which would constitute a substantial improvement to the primary structure.