Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: TE-FPU-0825-00340
Parcel: 13631011N

Review Status: Requires Resubmit

Review Details: FLOODPLAIN USE REVIEW v.1

Permit Number - TE-FPU-0825-00340
Review Name: FLOODPLAIN USE REVIEW v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
10/02/2025 Site Engineering - Standard REQUIRES RESUBMIT TE-FPU-0825-00340
4251 S PAULINE LN

Site Engineering Comments:
1. The proposed septic system for the ADU/casita is not allowable per City Code Part II Sec. 26-5.2. (14). The project would have to be tied into the existing sewer which runs down E Millmar Rd.
https://codelibrary.amlegal.com/codes/tucson/latest/tucson_az/0-0-0-19566
2. The entire parcel has been calculated to be within the erosion hazard setback area of the Pantano Wash.
https://codelibrary.amlegal.com/codes/tucson/latest/tucson_az/0-0-0-19545 - JD_26-5
3. The calculated Base Flood Elevation is 2750.4 feet NAVD88. This makes the required Finished Floor Elevation (FFE) for this proposal 2751.4. Because this project lies within the erosion hazard area of the Pantano wash, there are only a few ways to complete construction which comply with floodplain standards. These may be cost prohibitive.
4. Floodplain Administration will be added to the next review cycle for this FPU and the associated RES permit, TC-RES-0124-00519.

Ryan Insalaco
Engineering Associate
ryan.insalaco@tucsonaz.gov