Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Review Status: Requires Resubmit

Review Details: FLOODPLAIN USE REVIEW v.1

Permit Number - TE-FPU-0823-00284
Review Name: FLOODPLAIN USE REVIEW v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
08/10/2023 Site Engineering REQUIRES RESUBMIT 1. The proposed residence must be elevated one foot above the base flood elevation in the area, 2534.99 feet above sea level. Please indicate in the plans that the building will be elevated at or above 2535.99 feet above sea level. The building will require an elevation certificate to be filled out by a registered land surveyor both prior to the pouring of the foundation and after the completion of construction.

Lianne Evans
lianne.evans@tucsonaz.gov