Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: TE-FPU-0526-00210
Parcel: 116120170

Review Status: Requires Resubmit

Review Details: FLOODPLAIN USE REVIEW v.2

Permit Number - TE-FPU-0526-00210
Review Name: FLOODPLAIN USE REVIEW v.2
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
09/11/2026 Site Engineering REQUIRES RESUBMIT Site Engineering Review

TE-FPU-0526-00210
1212 W DELAWARE ST

Date of Transmittal: 9/11/2026
Description: Middle Housing Duplex
Related to: TD-DEV-0826-00230 & TC-RES-0526-02433

City of Tucson Code:
https://www.tucsonaz.gov/Departments/Planning-Development-Services/Codes

Ch 26 of the City Code:
https://codelibrary.amlegal.com/codes/tucson/latest/tucson_az/0-0-0-19333

Standards Manual for Drainage Design and Floodplain Management:
https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/engineering-code/cot-drainage-manual-searchable.pdf

Site Engineering comments are as follows:

1. Previous comment not addressed: “2. The Base Flood Elevation (BFE) will need to be determined from a Flood Plain Report in order to determine the finished floor elevation (FFE) of the proposed structure.”
2. Provide a Hydrology Study/Report with encroachment analysis sealed by an engineer as defined in the COT Drainage Manual. Review and approval of the report are required to establish the base flood elevation (BFE), thereby establishing the required finished floor elevation (FFE) of the sleeping quarters.
3. This report is also required to show that the placement of the structure within the floodplain meets the conditions set forth in Ch. 26 of the City Code. More particularly Sec. 26-5.2. Floodway fringe development, “(3) Not generate adverse impacts, including but not limited to erosion, upstream or downstream. (5) Not increase the base flood elevation more than one-tenth of a foot, as measured from the property boundary. (6) Not result in higher floodwater velocities which significantly increase the potential for flood or erosion damage. (9) Place the lowest (including basement) floor one (1) foot above the base flood elevation. Residential construction shall have the lowest floor elevated to or above the regulatory flood elevation. (11) Place service equipment and mechanical items, including but not limited to water heaters, heating/cooling equipment, ductwork, electrical service panels and/or other facilities, as deemed necessary by the floodplain administrator or designee, at or above the regulatory flood elevation.”
4. Review and approval of this Report, along with a Final Elevation Certification sealed by an RLS stating that the structure is compliant with the Regulatory Flood Elevation (RFE) are required.
5. Additional comments may be forthcoming depending on the content of files submitted for subsequent review cycles.

To re-submit, visit the Tucson Development Center Online at:
https://tdc-online.tucsonaz.gov/#/home

Engineering Associate: Ryan Insalaco
ryan.insalaco@tucsonaz.gov