Permit Review Detail
Review Status: Requires Resubmit
Review Details: FLOODPLAIN USE REVIEW v.1
Permit Number - TE-FPU-0525-00203
Review Name: FLOODPLAIN USE REVIEW v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 06/20/2025 | Site Engineering - Standard | REQUIRES RESUBMIT | TE-FPU-0525-00203 2812 N MOUNTAIN AV Site engineering comments are as follows: 1. This project site is mapped within a FEMA Flood Hazard Zone. Per the NFIP (National Flood Insurance Program) managed by FEMA, for a substantial improvement if a project site is within the floodplain - the sum of all improvements within any ten year period is limited to 50% of the value of the structure or the structure must be improved to floodplain standards (or verified that it is up to floodplain standards). According to Pima county assessor’s records the value of the existing house is $181,090 (65% of the full cash value from the county assessor’s). That puts the proposed work of $24,500, when added to the previous improvements, at 57.0% which is over the 50% and therefore is classified as a substantial improvement. So you can either reduce the scope of the project, provide a higher appraisal of the house, or bring the house and proposed work to floodplain standards. 2. Please specify if labor is included in the cost estimate. If you have any questions don’t hesitate to reach out to me. Isaac Tineo isaac.tineo@tucsonaz.gov |