Permit Review Detail
Review Status: Requires Resubmit
Review Details: FLOODPLAIN USE REVIEW v.1
Permit Number - TE-FPU-0525-00202
Review Name: FLOODPLAIN USE REVIEW v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 05/28/2025 | Site Engineering - Standard | REQUIRES RESUBMIT | TE-FPU-0525-00202 2812 N MOUNTAIN AV Site engineering comments are as follows: 1. This project lies within a recognized floodplain and requires a Floodplain Use Permit (FUP) with an elevation certificate. The base flood elevation (BFE) is 2385.48ft NAVD88. This requires that the finished floor elevation (FFE) of the lowest floor of the ADU be constructed at or above 2386.48ft NAVD88. Be sure to show the FFE on the site plan of the submittals. 2. The FUP must be approved and issued prior to issuance of the preliminary elevation certificate. Ryan Insalaco – ryan.insalaco@tucsonaz.gov |