Permit Number: TE-FPU-0523-00201
Parcel: 11517123A

Review Status: Requires Resubmit

Review Details: FLOODPLAIN USE REVIEW v.1

Permit Number - TE-FPU-0523-00201
Review Name: FLOODPLAIN USE REVIEW v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
05/18/2023 Site Engineering REQUIRES RESUBMIT 1. For this structure to be compliant with the floodplain code, the finished floor elevation of the garage will need to be a foot above the base flood elevation or the garage will need to be flood vented. See email sent to Griego Lu on 5/18/23 for more information on these options.
2. In addition to the elevation or flood venting, all utilities (electrical components, HVAC, water heaters, etc.) in the building must be raised above the regulatory flood elevation. This will need to be certified on an elevation certificate that is stamped by a surveyor.

Provide an updated plan with details on either elevating the building or flood venting and notes on elevating the utilities.