Permit Review Detail
Review Status: Requires Resubmit
Review Details: FLOODPLAIN USE REVIEW v.2
Permit Number - TE-FPU-0425-00151
Review Name: FLOODPLAIN USE REVIEW v.2
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 05/19/2025 | Site Engineering - Standard | REQUIRES RESUBMIT | TE-FPU-0425-00151 2626 E TOWNER ST Site Engineering comments are as follows: 1. The proposed home addition cost quote is $63,085. The estimated maximum value for this project to remain “Non-Substantial” is $61,870. If the increase in the value of the structure is over the non-substantial threshold, the entire structure may need to be brought to current floodplain standards. 2. There are a few options – a. Provide a cost estimate from the contractor that is lower than the substantial threshold. b. Provide documentation from a registered land surveyor that the finished floor of the existing structure is already at or above 2414.81ft NAVD88. c. Provide an appraisal for the structure in excess of two times the cost estimate of the project. The Substantial Improvement threshold value was calculated by taking the Full Cash Value of the parcel on the Assessor’s Site. $190,369 x 0.65 x .5 = Threshold The 0.65 is the estimate for the value of the structure. Half of that is the threshold of $61,870. Ryan Insalaco – ryan.insalaco@tucsonaz.gov |