Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit Review Detail
Review Status: Requires Resubmit
Review Details: FLOODPLAIN USE REVIEW v.1
Permit Number - TE-FPU-0425-00123
Review Name: FLOODPLAIN USE REVIEW v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 06/11/2025 | Floodplain Administration Review - Standard | REQUIRES RESUBMIT | Provide drainage report in compliance with City of Tucson drainage manual to include city's peak flow estimator, city scour calculation, with plans showing proposed waterline in alignment perpendicular to flow direction and set below calculated scour depth, and ERR Report in compliance with Tech Stnd 4-03. Please call or email for copies of city manual, spreadsheet, and guidance for city ERR Report, etc if needed. Also provide a copy of signed statement from the neighbouring subdivision to the north that provides authorization to do work in their common area. A facility permit application may be required from Pima County Regional Flood Control District. Additional comments may be forthcoming upon submittal of the required review documents. - Elizabeth Leibold, P.E., CPM, CFM, Civil Engineer, Dept of Transportation and Mobility, City of Tucson, 520-429-4905 (wk cell) | ||
| 06/11/2025 | ROW Engineering Review - Standard | REVIEW COMPLETED | ROW permit required for new water main |