Permit Review Detail
Review Status: Requires Resubmit
Review Details: FLOODPLAIN USE REVIEW v.1
Permit Number - TE-FPU-0423-00187
Review Name: FLOODPLAIN USE REVIEW v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 04/28/2023 | Site Engineering | REQUIRES RESUBMIT | 1. The new garage will need to be brought to floodplain regulation, either by elevating the finished floor to the Regulatory Flood Elevation (I estimate around a 1 foot elevation). Or the garage can be floodvented by adding floodvents to at least 2 walls. If the vents are non-engineered (I.E, air vents), the net open area in sq inches must exceed the garage floor area in sq ft. If engineered vents (I.E, smart vents, flood vents, etc), the certified floor area must match or exceed the actual floor area. Email scott.haseman@tucsonaz.gov your choice and I can provide more information on either choice. Scott Haseman scott.haseman@tucsonaz.gov |