Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: TE-FPU-0423-00187
Parcel: 123061100

Address:
2224 E ADAMS ST

Review Status: Requires Resubmit

Review Details: FLOODPLAIN USE REVIEW v.1

Permit Number - TE-FPU-0423-00187
Review Name: FLOODPLAIN USE REVIEW v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
04/28/2023 Site Engineering REQUIRES RESUBMIT 1. The new garage will need to be brought to floodplain regulation, either by elevating the finished floor to the Regulatory Flood Elevation (I estimate around a 1 foot elevation). Or the garage can be floodvented by adding floodvents to at least 2 walls. If the vents are non-engineered (I.E, air vents), the net open area in sq inches must exceed the garage floor area in sq ft. If engineered vents (I.E, smart vents, flood vents, etc), the certified floor area must match or exceed the actual floor area.

Email scott.haseman@tucsonaz.gov your choice and I can provide more information on either choice.

Scott Haseman
scott.haseman@tucsonaz.gov