Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: TE-FPU-0326-00110
Parcel: 126120500

Address:
421 N DESERT SV

Review Status: Approved

Review Details: BUILDING DEFERRED SUBMITTAL REVIEW v.1

Permit Number - TE-FPU-0326-00110
Review Name: BUILDING DEFERRED SUBMITTAL REVIEW v.1
Review Status: Approved
Review Date Reviewer's Name Type of Review Description Status Comments
09/14/2026 Site Engineering Express APPROVED ::EDIT 9/14/2026 - Approved, appraisal submitted on 9/11/2025 and work will remain under 50% value of structure. ::

_____________________________________________________________________________

Permit: TE-FPU-0326-00110
Location: 421 N DESERT SV
Review Date: 9/10/2026

Site Engineering Comments:

Not approved – The revised cost of the improvements is 28.22 percent of the value of the existing structure. The total cost of all improvements to the structure in any 10-year period must not exceed 50 percent of the value of the structure. With previous permit(s) T21OT00119 = 28% and revised TE-FPU-0326-00110 = 28.22%, respectively, the total improvement is now exceeding the limit for substantial improvement in the 10-year span and equals 56.22%.

ONE of the following steps is now necessary:
1. Revise the cost estimate and reduce scope to remain under the 50% threshold.
OR
2. Provide an appraisal from a registrant that demonstrates that the value of the structure is higher than the determined value from the Pima County Assessor.
OR
3. The structure would need to meet floodplain compliant elevation, there are no determinations for what regulatory flood elevation is at 421 N DESERT SV, therefore, both a hydrology study to determine the base flood elevation would need to be produced by a registered engineer or hydrologist AND a survey would need to be completed to determine if the existing structure is elevated 1-FT above the base flood elevation. If it is not, then the entire structure would need to be raised to the regulatory flood elevation (1-FT above the base flood elevation).

Only one of the three options above is necessary to approve the revised building permit (TC-RES-1225-06182).

NEXT STEPS: Resubmit to this floodplain use permit on how the applicant/owner wishes to proceed and submit any supplemental documentation that would support the above options.

If you have any questions or concerns, please contact Dylan Molina. Dylan.Molina@tucsonaz.gov & Site-Engineering@tucsonaz.gov