Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: TE-FPU-0326-00106
Parcel: 124090070

Review Status: Requires Resubmit

Review Details: FLOODPLAIN USE REVIEW v.4

Permit Number - TE-FPU-0326-00106
Review Name: FLOODPLAIN USE REVIEW v.4
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
08/05/2026 Site Engineering REQUIRES RESUBMIT Not Approved – until historic status can be maintained through review of SD-0526-00073, the floodplain use permit (TE-FPU-0326-00106) cannot be approved or issued.

The proposed improvement for solar panels exceeds Substantial Improvement under National Flood Insurance Program (NFIP). The current improvement, and past improvements in the past 10 years equate to 61.16% of the value of the structure; typical structures in FEMA AE floodplain must maintain improvements under 50% of the value of the structure for a 10-year period. However, historic structures are exempt from substantial improvement. Therefore, approval for SD-0526-00073 is required prior to issuance of floodplain use permit.