Permit Review Detail
Review Status: Requires Resubmit
Review Details: FLOODPLAIN USE REVIEW v.1
Permit Number - TE-FPU-0323-00124
Review Name: FLOODPLAIN USE REVIEW v.1
Review Status: Requires Resubmit
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
03/08/2023 | Site Engineering | REQUIRES RESUBMIT | The calculated Base Flood Elevation (BFE) for this structure is 2463.6 ft NAVD88. Therefore the regulatory flood elevation (and minimum FFE) is 2464.6 ft NAVD88. Please revise FFE on plans To clarify, this structure is directly between two washes (Columbus Wash and Columbus Wash Overflow/Midway Wash). Currently your calculated FFE is based off the WSEL of Columbus Wash; however, to account for the higher BFE of Columbus Wash Overflow/Midway Wash, I have interpolated from both BFE's across the same cross-sections based on distance from the channel center. Scott Haseman scott.haseman@tucsonaz.gov |