Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: TE-FPU-0226-00056
Parcel: 110070960

Review Status: Requires Resubmit

Review Details: FLOODPLAIN USE REVIEW v.2

Permit Number - TE-FPU-0226-00056
Review Name: FLOODPLAIN USE REVIEW v.2
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
08/03/2026 Site Engineering REQUIRES RESUBMIT Permit: TE-FPU-0226-00056
Location: 2614 N LA VERNE AV
Review Date: 8/3/2026

Please address all reviewer’s comments in a separate document with all required documents for resubmittal.

Site Engineering Comments:
1. T21CM03036 & T21OT00298 - permit for enclosing front patio (added 30.6% to substantial improvement) (never completed inspection)
2. CE-VIO1023-06057 - code violation for building without a permit
3. TC-RES-0925-04345 - first permit to rectify code violation (attached ADU) (should be withdrawn)
4. TC-RES-0526-02497 & TE-FPU-0226-00056 - second attempt to rectify code violation by reduced scope (garage and back patio)

5. Substantial Improvement Calculation: value of the structure as a new build per the appraiser ($185,482) and the cost-estimate provided ($69,296), percentage of proposed improvements: ($69,296)/($185,482) = 37.36%

6. Due to previous improvements in 2021, which added 30.6%, the overall improvement over the past 10-years is 30.6 + 37.36 = 67.96%; this percentage is over 50% and triggers Substantial Improvement per City of Tucson Floodplain Regulation. At this point there are two options:
a. Raise all finished floor elevations (existing and additions) to 1'-11" above natural grade. This is the elevation required to meet City of Tucson Floodplain Regulation for FEMA XS100_1ft.
OR
b. Reduce the scope of the proposal, which may include removing portions of already built addition without a permit, to remain under substantial improvement. Due to the 30.6% in 2021 (which stays with the structure until 2031), current budget to remain UNDER Substantial Improvement: (19.4%)($185,482) = $35,983.

If you have any questions or concerns, please contact Dylan Molina. Dylan.Molina@tucsonaz.gov