Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: TE-FPU-0126-00011
Parcel: 11918027A

Review Status: Requires Resubmit

Review Details: FLOODPLAIN USE REVIEW v.1

Permit Number - TE-FPU-0126-00011
Review Name: FLOODPLAIN USE REVIEW v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
01/23/2026 Site Engineering REQUIRES RESUBMIT Permit: TE-FPU-0126-00011
Location: 1302 W AJO WY Unit:UNIT 97
Review Date: 1/23/2026

Site Engineering Comments:
1. The proposed project/site resides within the recognized West Branch Santa Cruz River/FEMA AE Floodplain. This floodplain use permit will require an intermediate and final elevation certificate to be filled out by a registered land surveyor or engineer and submitted to the associated FPU permit. The intermediate is to be completed PRIOR to pouring the foundation. The final is completed after construction is completed.
i. It was found that the base flood elevation (BFE) for the proposed structure is 2397.1-FT NAVD 88. This will require a minimum finished floor elevation (FFE) of 2398.1-FT NAVD 88.
ii. For the resubmission of the FPU permit and the FBB permit, submit the construction plans with a general note that states, “structure to be built with FFE 2398.1-FT NAVD 88.”
2. Site Engineering will be unable to approve the FPU permit (TE-FPU-0126-00011) until a FBB permit is applied for. (Note: approval of FBB permit (# TBD) will be unable to be approved until associated FPU permit have been approved and issued.)

If you have any questions or concerns, please contact Dylan Molina.
Dylan.Molina@tucsonaz.gov