Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Number: TE-FPU-0124-00016
Parcel: 137031720

Review Status: Requires Resubmit

Review Details: FLOODPLAIN USE REVIEW v.1

Permit Number - TE-FPU-0124-00016
Review Name: FLOODPLAIN USE REVIEW v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
01/25/2024 Site Engineering REQUIRES RESUBMIT 1. Provide a site plan for the project and indicate that the finished floor elevation is one foot above the base flood elevation of 2490.5 feet NAVD88. Show which building this floodplain use permit is for.

For reference:
The elevation of the building must be certified by a registered land surveyor at two points during building: first before the pre-slab inspection, when the foundation forms are up, and second when construction is nearly complete, before any final inspections can take place. There will be holds put on the building permits that prevent these inspections until the elevation certificates are submitted to the floodplain use permit in the TDC Online portal.

Lianne Evans
lianne.evans@tucsonaz.gov