Plan Review Detail
Review Status: Requires Resubmit
Review Details: LAND DIVISION/SUBDIVISION v.6
Plan Number - TD-DIV-1224-00099
Review Name: LAND DIVISION/SUBDIVISION v.6
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| CDRC Post Review Express | PENDING ASSIGNMENT | ||||
| External Reviewers - Pima County Assessor Standard | REQUIRES RESUBMIT | Office of the Pima County Assessor 240 N. Stone Ave. Tucson, Arizona 85701 SUZANNE DROUBIE PIMA COUNTY ASSESSOR TO: City of Tucson Development Services FROM: Karl Christensen GIS Analyst II Pima County Assessor’s Office Karl.Christensen@pima.gov (520)724-3125 DATE: September 24, 2026 RE: Assessor’s Review and Comments Regarding: (SUBMITTAL 6) TD-DIV-1224-00099 – FRANKLIN ESTATES - FINAL PLAT * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ___ ___ Plat meets Assessor’s Office requirements. ___X___ Plat does not meet Assessor’s Office requirements. COMMENTS: • Unfortunately, while adding the items requested in the previous review, items that were present and required were removed in this submittal. Please make sure that all Perimeter/Lot/etc. lines have both distances and bearings. The bearings for the north and south lines of the subdivision are no longer present and must be included. The following are some “heads up” items that I noticed which should be addressed, but are not cause for this failed review by the Assessor’s Office: o General Notes #3 has a typo: “TOTAL MILES OF NEW PUBLIC STREETS ARE 0.00ILES”. o General Notes #5 is missing another point that the Franklin Street centerline is between (Between Silverbell Road and ???). o Legend symbology for those monuments to be set and those that were found are the same symbol. o Location Map arrow tip indicating the project area is gone, and so too is the shading of the project area. o The indicator of the found GLO Capped Pipe has the incorrect Range number (currently R15E, should be R13E). Also, the Section 14 & Section 15 annotation is swapped here, and in the Location Map. o In the bottom right Title Block: Neither this project, nor 03/131 M&P, are a portion of the Northeast Quarter of the Southwest Quarter of T14S R13E S11; this project is a portion of the Southwest Quarter of the Southwest Quarter of T14S R13E S11. o The plat’s Scale Bar is not fully constructed. o An observation on dimensional annotation: (Not speaking of dimensional annotation that either disappears or is added between submittals) Nearly every submittal has had at least one dimension change from the previous submittal, sometimes unprompted. This time it was an unprompted change to the calculated bearing and distance for the common line between Lots 1 & 2. I’m not sure what to think about how regularly the dimensional annotation seems to change, but I certainly hope that at Recordation they are all as they should be as designed. NOTE: THE ASSESSOR’S CURRENT INVOLVEMENT IN PROCESSING ITS MAPS TO DIGITAL FORMAT IS EXPEDITED GREATLY BY EXCHANGE OF DIGITAL DATA. IN THE COURSE OF RECORDING THIS SUBDIVISION PLAT YOUR ASSISTANCE IN PROVIDING THIS OFFICE WITH AN AUTOCAD COPY WOULD BE GREATLY APPRECIATED. AUTOCAD DWGS CAN BE SENT TO ASRGIS@PIMA.GOV AND/OR THE EMAIL ABOVE. THANK YOU FOR ANY DIGITAL DATA PREVIOUSLY SUBMITTED. |
|||
| Site Engineering | REQUIRES RESUBMIT | Permit Activity Number: TD-DIV-1224-00099 (2nd Review) Project: 2 Lot Split Application Type: Land Division/Subdivision Location: 1361 W FRANKLIN ST Review Date: 9/16/2026 Reviewer: Marco Contreras – Engineering Associate Reviewer Contact Information: marco.contreras@tucsonaz.gov Related cases: Plan review for the above-referenced Land Division application has been completed by Site Engineering. This review was conducted for compliance with applicable land division criteria, including the City of Tucson Unified Development Code (UDC), Administrative Manual (AM), and Technical Standards Manual (TSM) sections governing plat and land split applications, subdivision standards, and all applicable site standards. The following Site Engineering comments must be addressed prior to approval of this application. To help facilitate a timely resubmittal, please provide updated plans and calculations along with a written response to each comment individually, indicating what action(s) were taken and where the change can be found on the plans. DO NOT USE revision clouds on resubmittal drawings — revision clouds paired with deltas are solely reserved for post-permit revisions. Submit your response letter and updated plan set and reports as separate files. Applicable Code Links for quick/direct reference: City of Tucson Development Code: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Codes UDC Article 8 – Land division: https://codelibrary.amlegal.com/codes/tucson/latest/tucson_az_udc/0-0-0-6428 AM 2-07.0.0 – Plat Applications: https://codelibrary.amlegal.com/codes/tucson/latest/tucson_az_udc/0-0-0-8971 AM 2-08.0.0 - Land Split Applications: https://codelibrary.amlegal.com/codes/tucson/latest/tucson_az_udc/0-0-0-9108 COT Engineering Codes: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Codes/Engineering-Codes Site Engineering Review Comments: 1. Notary Block – Revise the notary statement as it still contains 2025 whereas it is currently 2026. 2. Title Block – Revise the title block to include "City Tucson" - Revise the location reference to read "City of Tucson, Pima County, Arizona." 3. Surveyor Registrant stamp – the stamp on the plat is not legible – revise accordingly with new stamp. |