| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| Record Documents Express | PENDING ASSIGNMENT | ||||
| Site Engineering | REQUIRES RESUBMIT | TD-DEV-0223-00147 3101 S COUNTRY CLUB RD3. 1. See zoning comments 2. Ensure the resubmittal complies with the requirements of AM 2-08. |
|||
| Site Zoning | REQUIRES RESUBMIT | CDRC TRANSMITTAL TO: Development Services Department Plans Coordination Office FROM: Fernando Garcia PDSD Site Zoning Review Section PROJECT: Lot Split 2089 W Ajo Wy, Tucson, AZ 85713 TD-DIV-1224-00096 (2nd Review) TRANSMITTAL DATE: February 21, 2024 COMMENTS: Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed. Section 3.3.3.G.5.c UDC, An applicant has one year from the date of application to obtain approval of a site plan that complies with zoning and other development requirements in effect at the time of application, unless an ordinance adopted by Mayor and Council during this period states otherwise. A site plan application that has been in review for a period of one year and has not yet been approved is considered denied. To continue the review of a site plan for the property, a new site plan must be submitted that complies with regulations in effect at the time of re-submittal. The new submittal initiates a new one-year review period. One year Expiration date is December 13, 2025. SECTION 2-06.0.0: DEVELOPMENT PACKAGE (TENTATIVE PLATS AND SITE PLANS) Zoning and Land Use Notes -06.4.7.A.2 - List the gross area of the site/subdivision by square footage and acreage. 1. COMMENT: 2-06.4.7.A.2 – Per UDC Section 6.3-2, the minimum lot size for an R-1 lot is 7,000 sf. The western lot is shown to be 6,779. This will need to be increased to a minimum of 7,000 sf and the provided legal descriptions updated to reflect the change. ***For additional information on the any standard presented in this memo, please refer to the City of Tucson “Unified Development Code” – Administrative Manual Section 2-06 or Technical Standards noted in the comments. https://www.tucsonaz.gov/pdsd/all-codes-plans-determinations If you have any questions about this transmittal, contact Fernando Garcia at fernando.garcia2@tucsonaz.gov. RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development package and comment response letter. To resubmit visit Tucson Development Center at https://tdc-online.tucsonaz.gov/#/home. Instructions for resubmittal - https://www.tucsonaz.gov/files/pdsd/website/Resubmittals.pdf. |
|||
| TW New Development Review | REQUIRES RESUBMIT | TD-DIV-1224-00095 - Land Division_Lot Split v2 – 2089 W AJO WY Tucson Water New Area Development Section – 2nd Review on 03/10.2025 Tucson Water has the following comments regarding the proposed lot split: 1. Per the drawings in this submittal and Google StreetView photos, at least one the existing water meters serving the parent parcel (APN 19411570) are in an adjacent lot’s (APN 119411560’s) frontage onto the existing 6” PVC water main in Ajo Hwy. That makes at least one of the existing water meters serving the parent parcel a “remote meter” as defined in Tucson Water’s Remote Meter Policy No. IV-B.08, Eff. 07/14/2009. 2. Tucson Water’s Remote Meter Policy No. IV-B.08, states in part, “When a parcel, which does not front a Tucson Water main, wishes to connect to Tucson Water, a remote meter will not be an authorized mechanism for obtaining water.” 3. To split the parent parcel as shown on this submittal, the existing water meter(s) will have to be relocated to comply with Tucson Water’s Remote Meter Policy No. IV-B.08, Eff. 07/14/2009. This policy requires all of the following: a. Each of the existing or proposed lots to have a minimum of 15’ of real property frontage onto the usable length of an existing or new public water distribution main, and the condition of that water distribution main must be such that it can be tapped to serve the proposed lots. b. The public water distribution main must be within a public or private street, public alley, water easement or public utility easement granted to the City of Tucson that shares a common boundary with the existing or proposed lot. c. The water meter serving each existing or proposed lot must be located within that lot’s minimum of 15’ of real property frontage onto an existing or new public water distribution main. d. The private water service line from the water meter for the existing or proposed lot to the building on the lot must not extend into any of the adjacent lots. e. The private water service line from the water meter to any building may not be located within a private water or private utility easement across an adjacent lot to the water main, as easements are not real property. 4. Please contact Tucson Water’s New Services Section and arrange for the relocation of the existing water meters as necessary to comply with Tucson Water’s Remote Meter Policy No. IV-B.08, Eff. 07/14/2009. 5. Documentation that arrangements have been made with Tucson Water’s New Services Section to relocate the existing water meters as necessary to comply with Tucson Water’s Remote Meter Policy No. IV-B.08, Eff. 07/14/2009, must be submitted before Tucson Water can approve the proposed lot split. 6. A revised drawing showing the relocation of the existing water meters as necessary to comply with Tucson Water’s Remote Meter Policy No. IV-B.08, Eff. 07/14/2009, and a SINGLE Comment Response Letter that addresses all of the different reviewers comments is required. Note: The quality of the scanned documents in this submittal was so poor, that they were barely legible when zoomed in upon to see details. Please submit vector .pdf files (i.e .pdf files generated by computer software) rather than raster .pdf files (i.e. pdf files created by running a hardcopy through a scanner) if possible. If you must submit .pdf files created by scanning hardcopies, please make sur that they are scanned at 600 or more dots per inch. 7. A copy of Tucson Water’s Remote Meter Policy No. IV-B.08, Eff. 07/14/2009 may be obtained by sending an e-mail request for it to me at the e-mail address shown in my signature block. Any questions, comments or concerns about these comments may be directed to: Tim Rowe, P.E., Civil Engineer Tucson Water, New Development Section 201 N. Stone Avenue, #2-220 P.O. Box 27210 Tucson, AZ 85726-7210 (520) 837-2106 tim.rowe@tucsonaz.gov |
|||
| CDRC Application Completeness Express | REVIEW COMPLETED |