Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Plan Number: TD-DIV-1122-00012
Parcel: 13821007A

Review Status: Requires Resubmit

Review Details: LAND DIVISION/SUBDIVISION v.1

Plan Number - TD-DIV-1122-00012
Review Name: LAND DIVISION/SUBDIVISION v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
CDRC Post Review Express PENDING ASSIGNMENT
CDRC Review Coordinator Express PENDING ASSIGNMENT
Commercial Building PENDING ASSIGNMENT
Commercial Plumbing PENDING ASSIGNMENT
Fire New Construction PENDING ASSIGNMENT
New Services/JOC PENDING ASSIGNMENT
NPPO PENDING ASSIGNMENT
Residential Building PENDING ASSIGNMENT
Site Engineering PENDING ASSIGNMENT
Site Zoning PENDING ASSIGNMENT
OK to Submit - Zoning Fast REQUIRES RESUBMIT PDSD TRANSMITTAL FROM: PDSD Zoning Review PROJECT: San Fernando Heights – Lots 1-15 Development Package (1st Review) TD-DIV-1122-00012 TRANSMITTAL DATE: December 16, 2022 DUE DATE: December 13, 2022 COMMENTS: Please resubmit revised drawings along with a detailed response letter, which states how all Zoning Review Section comments were addressed. This plan has been reviewed for compliance with the Unified Development Code (UDC) Administrative Manual (AM) Section 2-06. Also, compliance with applicable development criteria for the proposed use as listed in the City of Tucson Uniform Development Code (UDC) and the UDC Technical Standards Manual (TSM). Section 3.3.3.G.5.c UDC, an applicant has one year from the date of application to obtain approval of a site plan that complies with zoning and other development requirements in effect at the time of application, unless an ordinance adopted by Mayor and Council during this period states otherwise. A site plan application that has been in review for a period of one year and has not yet been approved is considered denied. To continue the review of a site plan for the property, a new site plan must be submitted that complies with regulations in effect at the time of re-submittal. The new submittal initiates a new one-year review period. One-year Expiration date is November 20, 2023. CONTENT REQUIREMENTS 1. COMMENT: 2-06.4.2.D – The page number and total number of pages is not correct on sheets 7 – 13. 2. COMMENT: 2-06.4.3 – Provide the development package case number, TD-DIV-1122-00012, adjacent to the title block on all sheets. 2-06.4.7 - General Notes The following general notes are required. Additional notes specific to each plan are required where applicable. 2-06.4.7.A - Zoning and Land Use Notes 3. COMMENT: 2-06.4.7.A.4 – Review UDC TABLE 4.8-2: PERMITTED USES - URBAN RESIDENTIAL ZONES and provide the Use Specific Standards for a single family residence in the R-1 zone within General Note 3. 2-06.4.9 - Information on Proposed Development The following information on the proposed project shall be shown on the drawing or added as notes. 4. COMMENT: 2-06.4.9.H.5.1 – It does not appear that the proposed street cross section matches any of the cross sections shown in TSM Section 10 and may require a Technical Standards Modification Request (TSMR). Contact your PDSD Engineering reviewer for requirements. 5. COMMENT: 2-06.4.9.H.5.a – Clearly show where the 4 required on-street parking spaces will be located and clearly show that they will not encroach into to any driveway access. 6. COMMENT: 2-06.4.9.L – Keynote 11 calls out a “5’ LANDSCAPE EASEMENT” but appears to point to an SVT. Also, you are proposing “CA “B” LANDSCAPE BORDER”, why would you need an easement if you are proposing a common area or vice versa. 7. COMMENT: 2-06.4.9.V – Demonstrate how Postal Service will be accomplished. If gang mailboxes are proposed indicate the location to assure there are no conflicts with other requirements, such as pedestrian accessibility, utilities, and landscaping. If you have any questions about this transmittal, please contact Nicholas Martell at Nicholas.Martell@tucsonaz.gov. RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development package
CDRC Application Completeness Express REVIEW COMPLETED
OK to Submit - Engineering Fast REVIEW COMPLETED