Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Plan Number: TD-DIV-1122-00010
Parcel: 129121920

Address:
1207 E 31ST ST

Review Status: Requires Resubmit

Review Details: LAND DIVISION/LOT SPLIT v.1

Plan Number - TD-DIV-1122-00010
Review Name: LAND DIVISION/LOT SPLIT v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
Commercial Plumbing APPROVED
TW New Development Review APPROVED 1. Tucson Water has no objections to the proposed lot split.
2. The above comments are based on the limited preliminary information provided by the applicant and should not be construed as a complete review of the proposal. Any questions, comments or concerns about these comments may be directed to:

Tim Rowe, P.E., Civil Engineer
Tucson Water, New Development Section
201 N. Stone Avenue, #2-220
P.O. Box 27210
Tucson, AZ 85726-7210
(520) 837-2106
tim.rowe@tucsonaz.gov
Commercial Building NOT REQUIRED
Record Documents Express PENDING ASSIGNMENT
Residential Building REQUIRES RESUBMIT Provide the Shed square footage. A staoage building over 200 SF requires a three foot separation to property line or one hour fire rating on the wall parallel to the property line. And remove or fire rate any roof projection.
Site Engineering REQUIRES RESUBMIT North line lengths and line lengths separating lots on the Record of Survey do not match the lengths on the proposed legal descriptions. Please revise and resubmit.
Ensure that lengths match the desired layout.
Joshua Garcia
Engineering Associate
joshua.garcia@tucsonaz.gov
Site Zoning REQUIRES RESUBMIT CDRC TRANSMITTAL
TO: Development Services Department
Plans Coordination Office

FROM: Paul Camarena
PDSD Zoning Review Section
PROJECT: TD-DIV-1122-00010
1207 E 31ST ST
Land Split (1st Review)


TRANSMITTAL DATE: December 6, 2022

COMMENTS: Please resubmit revised drawings along a detailed response letter, which states how all Zoning Review Section comments were addressed.

This plan has been reviewed for compliance with the Unified Development Code (UDC) 8.3.1 Land Split and Administrative Manual (AM) Section 2-08. Also compliance with applicable development criteria for the proposed or existing use as listed in the City of Tucson Uniform Development Code (UDC) and the UDC Technical Standards Manual (TSM).

8.3.1. LAND SPLIT
2-08.5.0 CONTENT REQUIREMENTS

The drawing showing the proposed land split shall include the following:

Comment: Remove the arial for the survey. The existing block wall was built in the right of way, addition review from the Department of transportation will be required. Please contact David Stiffey David.Stiffey@tucsonaz.gov, Provide documentation from DTM that this wall is okay to be within the right of way.

C. The rights-of-way adjacent to or within the property, including streets and easements. The streets and easements must be labeled, dimensioned and purpose listed;
Comment: Provide the dimension for the alley to the north.

F. The setbacks of existing buildings and structures from existing and proposed property lines;
Comment: Provide all setback dimensions for the house (South) and the shed structure (north,east) Provide the height of the house to determine the required setback. In the R-2 zone the setback is the greater of six (6) feet, or two-thirds (2/3) the height of the structure’s wall facing each interior property line (Table 6.3-2.A).

Comment: Provide the height of the shed, the required setback is the greater of six (6) feet, or two-thirds (2/3) the height of the structure’s wall facing each interior property line. Provide the setback dimension for the shed to the north property line. The setback to the east property line can be reduced by with a neighbor’s setback waiver. To secure this waiver the following text shall be provided on the plot plan and be signed and dated by the owner of the property to the east for the shed:
My Name is____________________ and I am the owner of the property located at_______________________. I have reviewed the site plan and I have no objection to structure being located or constructed________ feet from the property line as depicted on the site plan.

Signature: _____________________________

Date: _________________________________



G. The land area of each proposed lot in square feet or acreage. If the property is developed, additional information, such as but not limited to FAR, lot coverage, vehicle and bicycle parking, may be needed;
Comment: Provide the lot coverage for parcel A.

If you have any questions about this transmittal, Contact Paul Camarena at (520) 837-4986 or by email Paul.Camarena@tucsonaz.gov

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised final plat.
CDRC Application Completeness Express REVIEW COMPLETED