| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| Record Documents Express | PENDING ASSIGNMENT | ||||
| Residential Engineering Fast | REQUIRES RESUBMIT | Permit: TD-DIV-1025-00096 Location: 1021 S 4TH AV Review Date: 11/3/2025 Site Engineering Comments: 1. For resubmission, it is required that the lot descriptions be their own separate documents rather than be the same file. Revise accordingly. 2. Provide the bearings for the proposed lot line within the legal description. Administrative Manual 2-08.5.B 3. See that all of zonings comments are addressed. If you have any questions or concerns, please contact Marco Contreras Marco.contreras@tucsonaz.gov |
|||
| Residential Zoning Fast | REQUIRES RESUBMIT | PDSD TRANSMITTAL FROM: PDSD Zoning Review PROJECT: TD-DIV-1025-00096 1021 S 4TH AV. – R-2 Land Split (1st Review) TRANSMITTAL DATE: November 3, 2025 DUE DATE: October 31, 2025 SECTION 2-08.0.0: LAND SPLIT 2-08.2.0 CONTENT REQUIREMENTS 1. COMMENT: 2-08.5.B – Provide the bearings for the proposed lot line within the legal description. 2. COMMENT: 2-08.5.E – Show the existing structure on the plan along with the size and heights of exterior wall. 3. COMMENT: 2-08.5.F – Provide perimeter yard setback dimension from the existing structure to the proposed lot line. 4. COMMENT: 2-08.5G – Provide a lot coverage calculation for the lot with the existing structure the meets the requirements of UDC Article 6.4.3 and the example shown on the Residential Plot Plan Requirements found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Building-Safety/Plan-Examples/Plot-Plan-Example. The Unified Development Code (UDC) can be found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Codes/Zoning-Code. If you have any questions about this transmittal, please contact Zone1.desk@tucsonaz.gov. |
|||
| CDRC Application Completeness Express | REVIEW COMPLETED | ||||
| Commercial Building Fast | REVIEW COMPLETED | ||||
| Commercial Plumbing Fast | REVIEW COMPLETED | ||||
| Residential Building Fast | REVIEW COMPLETED | ||||
| TW New Development Review Fast | REVIEW COMPLETED | For the proposed west parcel (Lot 1) there is an existing 6" water main in South 4th Avenue. There is also an existing water meter for Lot 1. In Railroad Avenue there is an existing 4" water main, the north end of which terminates in the vicinity of the southeast property corner of the proposed east parcel (Lot 2). Therefore, to serve Lot 2, a main extension to the north will probably be required to ensure that the proposed Lot 2 has 15' of frontage along the water main. |