Plan Review Detail
Review Status: Requires Resubmit
Review Details: LAND DIVISION/LOT SPLIT v.1
Plan Number - TD-DIV-0926-00059
Review Name: LAND DIVISION/LOT SPLIT v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| Commercial Plumbing Fast | APPROVED | New water meter required for proposed Lot 1 | |||
| Record Documents Express | PENDING ASSIGNMENT | ||||
| Residential Building Fast | REQUIRES RESUBMIT | Show HCS / sewer line to verify if joint usage agreement may be required. | |||
| Site Engineering Fast | REQUIRES RESUBMIT | Permit Activity Number: TD-DIV-0926-00059 (1st Review) Project: Proposed land split of the existing parcel into two lots. Proposed Lot 1 will contain approximately 12,004 square feet and Proposed Lot 2 will contain approximately 6,708 square feet. Existing improvements and proposed parcel boundaries are shown on the submitted land split plan. The purpose of this application is to establish the two separate legal parcels in accordance with City of Tucson land split requirements. Application Type: Land Division/Lot Split Location: 2300 N TUCSON BL Review Date: 9/18/2026 Reviewer: Marco Contreras – Engineering Associate Reviewer Contact Information: marco.contreras@tucsonaz.gov Related cases: Plan review for the above-referenced Land Division application has been completed by Site Engineering. This review was conducted for compliance with applicable land division criteria, including the City of Tucson Unified Development Code (UDC), Administrative Manual (AM), and Technical Standards Manual (TSM) sections governing plat and land split applications, subdivision standards, and all applicable site standards. The following Site Engineering comments must be addressed prior to approval of this application. To help facilitate a timely resubmittal, please provide updated plans and calculations along with a written response to each comment individually, indicating what action(s) were taken and where the change can be found on the plans. DO NOT USE revision clouds on resubmittal drawings — revision clouds paired with deltas are solely reserved for post-permit revisions. Submit your response letter and updated plan set and reports as separate files. Applicable Code Links for quick/direct reference: City of Tucson Development Code: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Codes UDC Article 8 – Land division: https://codelibrary.amlegal.com/codes/tucson/latest/tucson_az_udc/0-0-0-6428 AM 2-07.0.0 – Plat Applications: https://codelibrary.amlegal.com/codes/tucson/latest/tucson_az_udc/0-0-0-8971 AM 2-08.0.0 - Land Split Applications: https://codelibrary.amlegal.com/codes/tucson/latest/tucson_az_udc/0-0-0-9108 COT Engineering Codes: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Codes/Engineering-Codes Site Engineering Review Comments: 1. For resubmission - provide new legal descriptions for each individual parcel being created through this land split application. Each description must be a stand-alone file for recording purposes. |
|||
| Site Zoning Fast | REQUIRES RESUBMIT | 1. COMMENT: Only the legal description for Lot 2 was provided. Provide legal description for Lot 1. Each description should be on a separate page. Contact Fernando Garcia, Lead Planner, Site Zoning at fernando.garcia2@tucsonaz.gov. |
|||
| CDRC Application Completeness Express | REVIEW COMPLETED | ||||
| Commercial Building Fast | REVIEW COMPLETED | ||||
| ROW Review -Land Division/Lot Split | REVIEW COMPLETED | ||||
| TW New Development Review Fast | REVIEW COMPLETED | Tucson Water has no objection to the proposed lot split, subject to the following: Each lot shall have its own independent water meter and service. Lot 2 can be served from the existing 6-inch CA water main along E. Edison Street. Please contact Tucson Water New Services to coordinate the new meter installation. Show the existing meter location, identify the lot it will serve, and show the proposed meter and private water line routing for Lot 2. All private water lines shall remain entirely within the boundaries of the lot served. No private water lines shall cross the proposed property lines or supply buildings on another lot. Verify the water connections serving all existing buildings. Any connections crossing the proposed lot lines shall be disconnected and rerouted to the appropriate lot’s independent service. Connections to structures proposed for removal shall be properly disconnected and capped. |