Plan Review Detail
Review Status: Requires Resubmit
Review Details: LAND DIVISION/SUBDIVISION v.2
Plan Number - TD-DIV-0923-00102
Review Name: LAND DIVISION/SUBDIVISION v.2
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| External Reviewers - Pima County Wastewater (RWRD) | APPROVED | Final Plat Approval Record Number: P23WS00050 Project Name: 201 E. Aviation Dr, Lots 1-3. Approval issue date: 10/25/2023. Applicant: JAS Engineering, Attn: Jeff Stanley. Owner Name: Kyriacou Kyriacos. Owner Address:1575 E Camino Padre Isidoro, Tucson. Az. 85718. The Pima County Development Services Department has reviewed the above referenced project and hereby APPROVES the Final Plat, based upon PCRWRD Engineering Design Standards (EDS) 2022. Please note any changes and/or revisions to the approved plans shall require a re-submittal to the department for review and evaluation |
|||
| External Reviewers - Tucson Airport Authority | APPROVED | December 12, 2023 Planning and Development Services City of Tucson 201 North Stone Avenue Tucson, AZ. 85701 RE: TD-DIV-0923-00102, 2nd Submittal, Minor subdivision for 3 lots / 201 E Aviation Dr, Tucson, AZ. 85714, Received November 8, 2023 To whom this may concern, Thank you for the opportunity to comment on TD-DIV-0923-00102, 2 nd Submittal, a development plan for minor subdivision for 3 lots for future residential uses at 201 East Aviation Drive. This development is located in the S.W. quarter of the N.E. quarter of Section 36, Township 14S, Range 13E, of the Gila and Salt River Meridian. The development site occupies parcel number 120-06-346B, covers approximately 0.528 ± acres, and is zoned as Residence 2 Zone (R-2). The nearest major roadway intersection is South 4th Avenue and East Aviation Drive, approximately 50 feet to the southwest of the subject development. This site does lie within the Tucson International Airport avigation easement requirements and public disclosure area, FAA traffic pattern airspace, and FAA Part 77 airspace. The Tucson Airport Authority approves the proposed project and is not requiring a resubmittal. Please do not hesitate to contact me if you have any questions or concerns regarding this comment letter. I can be reached by email at srobidoux@flytucson.com or by telephone at 520-573-4811. Respectfully, Scott Robidoux, C.M. Manager of Planning |
|||
| Site Engineering | APPROVED | ||||
| Site Zoning | APPROVED | ||||
| CDRC Post Review Express | PENDING ASSIGNMENT | ||||
| New Services/JOC | REQUIRES RESUBMIT | TD-DIV-0923-00102 - Land Division_Subdivison v2 – 201 E AVIATION DR 1. Most of Tucson Water’s review comments for the 1st submittal were not addressed. They are reproduced below for your convenience. 2. On the Supplemental Plan: Tucson Water’s records indicate that there are four (4) water meter boxes at the rear of the parent parcel, two of which contain water meters and two of which do not. Show the existing water meter boxes, and show which water meter boxes contain existing water meters and which do not. 3. On the Supplemental Plan: Show the existing private water service line between each existing water meter box that contains an existing water meter and the existing building it serves. Note: Tucson Water’s Remote Meter Policy No. IV-B.08, Eff. 07/14/2009 requires all of the following: a) Each lot must have its own water meter. b) The water meter for any given lot must lie within that lot’s frontage onto a public street, private street, or utility easement that contains an existing water main that can serve that lot. c) The private water line from a water meter to building must lie on just one lot. The private water line from a water meter to a building may not encroach into, or cross a second lot, even in a private water easement. In other word, the private water line may not cross any existing or proposed lot line. In this particular case: d) A water meter in Lot 1’s street frontage may only serve buildings on Lot 1. e) An existing water meter in the water easement at the rear of Lot 2 may only serve buildings on Lot 2. f) The existing water meter in the water easement at the rear of Lot 3 may only serve buildings on Lot 3. 4. On the Supplemental Plan: Show any necessary removal/relocation of water meters or private water lines. And show any necessary new water meters. 5. On the Supplemental Plan: Show by Keynote 8 that new water service is required for proposed Lot 1. 6. On the Final Plat: Show the recording information for the water easement granted to Nation City Water Co. 7. Provide a copy of the easement for water pies and /or mains and rights incident thereto, shown in the title report, as having been recorded at Book 265 Page 419. And show this easement on the final plat. 8. Please submit a comment response letter with the revised Supplemental Plan and Final Plat. 9. A copy of Tucson Water’s Remote Meter Policy No. IV-B.08, Eff. 07/14/2009 may be obtained by sending an e-mail request for this policy to me at the e-mail address in my signature block. 10. Any questions, comments or concerns about these comments may be directed to: Tim Rowe, P.E., Civil Engineer Tucson Water, New Development Section 201 N. Stone Avenue, #2-220 P.O. Box 27210 Tucson, AZ 85726-7210 (520) 837-2106 tim.rowe@tucsonaz.gov |
|||
| ROW Engineering Review | REQUIRES RESUBMIT | TD-DIV-0923-00102 (201 E AVIATION DR TUCSON, AZ 85714) 2nd Review Please resubmit revised drawings along with a detailed response letter which states how all comments were addressed. Comments: 1. 2-Right-of-Way Permit Plan_v1 shows 4’ sidewalks. 5’ sidewalks are required. Faffs Riederer Faffs.Riederer@tucsonaz.gov Abbreviations: City of Tucson Code (COTC), Unified Development Code (UDC) Administrative Manual (AM), Technical Standards Manual (TSM), Street Design Guide (SDG), Pima Association of Governments Standard Details (P. A. G. SD), Access Management Guidelines (AMG), Major Streets and Routes Plan (MS&R). |
|||
| CDRC Application Completeness Express | REVIEW COMPLETED |