Plan Review Detail
Review Status: Requires Resubmit
Review Details: LAND DIVISION/SUBDIVISION v.1
Plan Number - TD-DIV-0826-00053
Review Name: LAND DIVISION/SUBDIVISION v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| External Reviewers - Pima County Addressing Standard | APPROVED | Re: TDC External Review PERMIT: TD-DIV-0826-00053 Please Sign-In DUE: 9/18/2026 David Wilging<David.Wilging@pima.gov> CDRC Good morning, Pima County Addressing approves TD-DIV-0826-00053. Thank you, David Wilging Planner I - Addressing Division Pima County Development Services 201 N. Stone Avenue 1st Floor Tucson, Arizona 85701 520-724-6381 | |||
| NPPO Standard | APPROVED | The NPPO Waiver for this project site was approved during the development package review under activity number TD-DEV-0626-00153. Thank you. Chad Keller, PLA chad.keller@tucsonaz.gov |
|||
| CDRC Post Review Express | PENDING ASSIGNMENT | ||||
| External Reviewers - Pima County Assessor Standard | REQUIRES RESUBMIT | Office of the Pima County Assessor 240 N. Stone Ave. Tucson, Arizona 85701 SUZANNE DROUBIE PIMA COUNTY ASSESSOR TO: Submittal Entity FROM: Deanna Medlin GIS Cartographer Pima County Assessor’s Office Deanna.Medlin@pima.gov (520)724-8203 DATE: September 18, 2026 RE: Assessor’s Review and Comments Regarding: TD-DIV-0826-00053 Lyons Grove Lots 1-63 & CA’s 1st Submittal * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * Plat meets Assessor’s Office requirements. __X___ Plat does not meet Assessor’s Office requirements. COMMENTS: THE TITLE BLOCK MUST BE IN THE LOWER RIGHT-HAND CORNER. IT MUST HAVE THE NUMBER OF LOTS OR UNITS OR BLOCKS OR ANY COMBINATION OF THESE. IT MUST HAVE THE COMMON AREAS LISTED, IF THERE ARE ANY. IT MUST HAVE THE SECTION, TOWNSHIP AND RANGE AND IF IT IS A RESUBDIVISION, IT MUST MENTION THE PLAT NAME AND THE MAP AND PLAT. THE LOCATION MAP MUST BE IN THE UPPER RIGHT-HAND CORNER AND MUST HAVE THE SECTION, TOWNSHIP AND RANGE. THE PROJECT AREA SHOULD BE OUTLINED OR HAVE AN ARROW POINT TO IT. GENERAL NOTES MUST HAVE THE GROSS AREA OF THE SUBDIVISION, THE NUMBER OF LOTS, THE NUMBER OF MILES OF NEW ROAD, PUBLIC OR PRIVATE, EVEN IF THE NUMBER IS 0, AND THE BASIS OF BEARING. THERE MUST BE A SECTION TIE, WITH A BEARING AND DIMENSION FROM THE SECTION CORNER OR QUARTER CORNER TO THE POINT OF TIE ON THE SUBDIVISION. *Unable to clearly locate SECTION TIE. THE PERIMETER LINE MUST BE SOLID AND THE HEAVIEST LINE WEIGHT ON THE PLAT. THE LOT LINES AND COMMON AREA LINES MUST BE SOLID AND THE NEXT HEAVIEST. LINES FOR EROSION SETBACKS, FLOODPLAIN LINES ETC. SHOULD BE THE LIGHTEST LINE WEIGHT AND BE DASHED OR DOT-DASHED. *Northwesterly Perimeter line is heaviest, but the rest of the perimeter lines are the same weight as the lot & common area lines on pages 1 & 2. THERE MUST BE BEARINGS AND DIMENSIONS FOR THE PERIMETER AND ALL LOT LINES AND ALL COMMON AREAS. ALL LOTS MUST BE NUMBERED AND HAVE SQUARE FOOTAGE. IF THE AREA IS TOO SMALL, THEY CAN HAVE A TABLE TO THE SIDE FOR THE SQUARE FOOTAGE. ALL HATCHING, STIPPLING, STRIPING ETC., MUST BE REMOVED IN THE FINAL PLAT, UNLESS ANOTHER AGENCY REQUIRES IT. IF SO, ALL LETTERING MUST HAVE THE HATCHING, ETC., CUT AWAY SO THEY ARE LEGIBLE. ALL STREETS MUST BE NAMED IN THE FINAL PLAT, AND HAVE DIMENSIONS, BEARINGS, AND CURVE DATA. *Street dimensions for E. LYONS PRIDE DRIVE are missing. ALL ADJACENT SUBDIVISIONS SHOULD BE NAMED, WITH MAP AND PLAT IN THE APPROPRIATE AREAS AROUND THE SUBDIVISION. OWNERSHIP PRINTED IN THE DEDICATION SECTION OR ELSEDWHERE IN THE PLAT MUST MATCH ASSESSOR DATA. *Our office reflects ownership as: TUCSON SCHOOL DISTRICT NO 1 NOTE: THE ASSESSOR’S CURRENT INVOLVEMENT IN PROCESSING ITS MAPS TO DIGITAL FORMAT IS EXPEDITED GREATLY BY EXCHANGE OF DIGITAL DATA. IN THE COURSE OF RECORDING THIS SUBDIVISION YOUR ASSISTANCE IN PROVIDING THIS OFFICE WITH AN AUTOCAD COPY WOULD BE GREATLY APPRECIATED. AUTOCAD DWGS CAN BE SENT TO THE EMAIL ABOVE AND/OR ASRGIS@PIMA.GOV. THANK YOU FOR ANY DIGITAL DATA PREVIOUSLY SUBMITTED. |
|||
| External Reviewers - Pima County Wastewater (RWRD) Standard | REQUIRES RESUBMIT | The applicant is responsible for obtaining review and approval by Pima County, for projects involving RWRD sewers, on-site wastewater treatment facilities and public water systems https://www.pima.gov/1766/Wastewater-Reclamation. The applicant must provide an Approval letter from RWRD, prior to PDSD Approving the permit. | |||
| Site Engineering Standard | REQUIRES RESUBMIT | Permit Activity Number: TD-DIV-0826-00053 (1st Review) Project: Final Plat for Lyons Grove, an FLD Subdivision, Lots 1-63 & Common Areas "A" and "B" Application Type: Land Division/Subdivision Location: 7555 E DOGWOOD ST Review Date: 9/3/2026 Reviewer: Marco Contreras – Engineering Associate Reviewer Contact Information: marco.contreras@tucsonaz.gov Related cases: Plan review for the above-referenced Land Division application has been completed by Site Engineering. This review was conducted for compliance with applicable land division criteria, including the City of Tucson Unified Development Code (UDC), Administrative Manual (AM), and Technical Standards Manual (TSM) sections governing plat and land split applications, subdivision standards, and all applicable site standards. The following Site Engineering comments must be addressed prior to approval of this application. To help facilitate a timely resubmittal, please provide updated plans and calculations along with a written response to each comment individually, indicating what action(s) were taken and where the change can be found on the plans. DO NOT USE revision clouds on resubmittal drawings — revision clouds paired with deltas are solely reserved for post-permit revisions. Submit your response letter and updated plan set and reports as separate files. Applicable Code Links for quick/direct reference: City of Tucson Development Code: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Codes UDC Article 8 – Land division: https://codelibrary.amlegal.com/codes/tucson/latest/tucson_az_udc/0-0-0-6428 AM 2-07.0.0 – Plat Applications: https://codelibrary.amlegal.com/codes/tucson/latest/tucson_az_udc/0-0-0-8971 AM 2-08.0.0 - Land Split Applications: https://codelibrary.amlegal.com/codes/tucson/latest/tucson_az_udc/0-0-0-9108 COT Engineering Codes: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Codes/Engineering-Codes Site Engineering Review Comments: 1. Title Block – Revise the title block to include "Pima County" - Revise the location reference to read "City of Tucson, Pima County, Arizona." 2. Provide the Final Plat Subdivision case number (TD-DIV-0826-00053) adjacent to the title block on each sheet of the plan set. 3. Per Arizona State Notary regulations, revise the acknowledgement |
|||
| Site Zoning Standard | REQUIRES RESUBMIT | Final Site Zoning approval for this permit cannot be granted until the related tentative plat, TD-DEV-0626-00153, is first approved. Contact Fernando Garcia, Lead Planner, Site Zoning at fernando.garcia2@tucsonaz.gov. |
|||
| CDRC Application Completeness Express | REVIEW COMPLETED | ||||
| CDRC Review Coordinator Express | REVIEW COMPLETED | CDRC added Addressing, RWRD, Assessor, SWG, TEP, to the workflow. FYI notice sent out to SWG & TEP | |||
| Commercial Building Standard | REVIEW COMPLETED | ||||
| Commercial Plumbing Standard | REVIEW COMPLETED | ||||
| Entitlements Standard | REVIEW COMPLETED | Conforms to approved PDP TP-ENT-1225-00024 | |||
| External Reviewers - Southwest Gas Standard | REVIEW COMPLETED | CDRC sent FYI Notice email sent. No further action is required. | |||
| External Reviewers - Tucson Electric Power (TEP) Standard | REVIEW COMPLETED | CDRC sent FYI Notice email sent. No further action is required. | |||
| Fire New Construction Standard | REVIEW COMPLETED | ||||
| New Services/JOC Standard | REVIEW COMPLETED | Tucson Water has no objection to the proposed final plat. The lot and street layout is consistent with the accepted Water Master Plan, TW-MWP-0726-00032, and the proposed water easement is shown on Sheet 2. | |||
| OK to Submit - Engineering Fast | REVIEW COMPLETED | ||||
| OK to Submit - Zoning Fast | REVIEW COMPLETED | ||||
| Residential Building Standard | REVIEW COMPLETED |