Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Plan Number: TD-DIV-0823-00100
Parcel: 13632002S

Review Status: Requires Resubmit

Review Details: LAND DIVISION/LOT SPLIT v.1

Plan Number - TD-DIV-0823-00100
Review Name: LAND DIVISION/LOT SPLIT v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
Residential Building APPROVED
Site Engineering APPROVED
Commercial Building NOT REQUIRED This is not commercial, see Residential Building comment.
Record Documents Express PENDING ASSIGNMENT
Commercial Plumbing REQUIRES RESUBMIT For the purposes of having a water meter, a parcel is required to have a minimum width of 15-feet of frontage on a water main. An easement is not considered to be frontage. Show how the two parcels will be provided with water. Reference: Tucson Water Remote Meter Policy, Number IV-B.08, dated 07/14/2009
Site Zoning REQUIRES RESUBMIT CDRC TRANSMITTAL

TO: Development Services Department

Plans Coordination Office

FROM: Paul Camarena

PDSD Zoning Review Section

PROJECT: 10922 E ESCALANTE RD

Land Split (1st Review)

TD-DIV-0823-00100

TRANSMITTAL DATE: August 30, 2023

COMMENTS: Please resubmit revised drawings along a detailed response letter, which states how all Zoning Review Section comments were addressed.

This plan has been reviewed for compliance with the Unified Development Code (UDC) 8.3.1 Land Split and Administrative Manual (AM) Section 2-08. Also compliance with applicable development criteria for the proposed or existing use as listed in the City of Tucson Uniform Development Code (UDC) and the UDC Technical Standards Manual (TSM).

8.3.1. LAND SPLIT


Comment: Per UDC section 7.8.3.C Acceptable types of Access “ Access easement , which is ingress-egress to a parcel provided over some other parcel through an area dedicated for such perpetual use” An ingress-egress easement is not allowed to cross over multiple parcels, with that being said street frontage will be required for parcel 2





If you have any questions about this transmittal, Contact Paul Camarena at (520) 837-4986 or by email Paul.Camarena@tucsonaz.gov

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised final plat.
TW New Development Review REQUIRES RESUBMIT TD-DIV-0823-00100 - Land Division_Land Split_Lot Split v1 – 10922 E ESCALANTE RD

1. The proposed land split does not comply with the requirements of Tucson Water’s Remote Meter Policy Number IV-B.08, dated 07/14/2009. Please revise as necessary in accordance with the following comments.

2. To comply with Tucson Water’s Remote Meter Policy, each lot must have a minimum of 15’ of real property frontage onto a street, alley or public water easement that contains an existing water distribution main that can serve the lots. An easement does not qualify as real property frontage.

3. In this particular case, to comply with Tucson Water’s Remote Meter policy, each lot must have a minimum of 15’ of frontage onto the existing 6” PVC water distribution main constructed in Escalante Road under Work Order (WO) 8916-063. No water meters may be connected to the existing 24” water transmission main in Escalante Road.

4. Please note that the existing 6” PVC water distribution main in Escalante Rd. does not front the entire frontage of the parent parcel. See Tucson Water’s NE361415 valve map and the as-built plan of WO 8916-063. These documents may be obtained by sending an e-mail request to Tucson Water’s Mapping / GIS Records Center at twmapinfo@tucsonaz.gov.

5. Also, please note that Tucson Water’s Remote Meter Policy also prohibits the private water service line from a water meter to a building on one parcel to be run across another parcel.

6. If the proposed lot layout cannot be revised in such a manner, Tucson Water’s Remote Meter Policy requires that a public water main extension be constructed to serve each new lot by the owner/developer at his or her own expense. And, if the water main extension will be located on private property, it will also need to be centered in a new, dedicated water easement that is a minimum of 15’ wide. The existing 15’ public utility easement on the property cannot be used for this purpose as it was not granted to Tucson Water, and it is too narrow to accommodate all of the other utilities within this easement and an extension of the public water system.

7. Please revise the site plan to show the existing 24” water transmission main, and the existing 6” distribution main in Escalante Road and how the two parcels will be provided with water.

8. You may request a copy of Tucson Water’s Remote Meter Policy, by sending an e-mail to me at the e-mail address shown below.

9. Any questions, comments or concerns about these comments may be directed to:

Tim Rowe, P.E., Civil Engineer
Tucson Water, New Development Section
201 N. Stone Avenue, #2-220
P.O. Box 27210
CDRC Application Completeness Express REVIEW COMPLETED