Plan Review Detail
Review Status: Requires Resubmit
Review Details: LAND DIVISION/SUBDIVISION v.4
Plan Number - TD-DIV-0724-00059
Review Name: LAND DIVISION/SUBDIVISION v.4
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| Commercial Plumbing | APPROVED | ||||
| External Reviewers - Pima County Wastewater (RWRD) | APPROVED | RWRD Approval letter has been provided. Sonya Bermudez MA. | |||
| Site Engineering | APPROVED | ||||
| Site Zoning | APPROVED | ||||
| CDRC Post Review Express | PENDING ASSIGNMENT | ||||
| External Reviewers - Pima County Assessor | REQUIRES RESUBMIT | Office of the Pima County Assessor 240 N. Stone Ave. Tucson, Arizona 85701 SUZANNE DROUBIE PIMA COUNTY ASSESSOR TO: City of Tucson Development Services FROM: Karl Christensen GIS Analyst II Pima County Assessor’s Office Karl.Christensen@pima.gov (520)724-3125 DATE: December 10, 2024 RE: Assessor’s Review and Comments Regarding: (SUBMITTAL 2) TD-DIV-0724-00059 – RIO AZUL – MLD R.O.S. * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * N/A_ Plat meets Assessor’s Office requirements. _N/A__ Plat does not meet Assessor’s Office requirements. COMMENTS: The Assessor’s Office does not review anything except Final Plats. If/When this activity item is required to be submitted as a Final Plat, please at that time include the Assessor’s Office in the review process. See below for the full boilerplate list of generalized requirements the Assessor’s Office reviews Final Plats for: The title block must be in the lower right-hand corner and it must have the number of lots or units or blocks or elements or any combination of these. It must have the Common Areas listed if there are any. It must have the section, township, and range and if it is a resubdivision, it must mention the plat name and the map & plat. The location map must be in the upper right-hand corner and must have the section, township, and range. The project area should be outlined and/or have an arrow pointing to it. General notes must have the gross area of the subdivision, the number of lots, the number of miles of new road, public or private (even if the number is 0), and the Basis of Bearings. There must be a section tie, with a bearing and dimension from the section corner or quarter corner to the point of tie on the subdivision. The perimeter line must be solid and the heaviest lineweight on the plat. The lot lines and Common Area lines must be solid and the next heaviest. Lines for erosion setbacks, floodplain lines etc. should be the lightest lineweight and be dashed or dot-dashed. There must be bearings and dimensions for the perimeter and all lot lines and all Common Areas. All lots and Common Areas must be numbered and have square footage. If the area is too small, there can be a table to the side for the square footage. All hatching, stippling, striping, etc. must be removed in the final plat, unless another agency requires it. If so, all lettering must have the hatching, etc. cut away so they are legible. All streets must be named in the final plat, and have dimensions, bearings, and curve data. All adjacent subdivisions should be named, with map and plat in the appropriate areas around the subdivision. Ownership printed in the Dedication section or elsewhere in the plat must match Assessor data. NOTE: THE ASSESSOR’S CURRENT INVOLVEMENT IN PROCESSING ITS MAPS TO DIGITAL FORMAT IS EXPEDITED GREATLY BY EXCHANGE OF DIGITAL DATA. IN THE COURSE OF RECORDING THIS SUBDIVISION YOUR ASSISTANCE IN PROVIDING THIS OFFICE WITH AN AUTOCAD COPY WOULD BE GREATLY APPRECIATED. AUTOCAD DWGS CAN BE SENT TO THE EMAIL ABOVE AND/OR ASRGIS@PIMA.GOV. THANK YOU FOR ANY DIGITAL DATA PREVIOUSLY SUBMITTED |
|||
| CDRC Application Completeness Express | REVIEW COMPLETED | ||||
| New Services/JOC | REVIEW COMPLETED | TD-DIV-0724-00059 - Land Division_Subdivision v4 – 5450 S PARK AV 2nd Review by Tucson Water New Area Development staff Tucson Water has no objections to the proposed lot split. Any questions, comments or concerns about these comments may be directed to: Tim Rowe, P.E., Civil Engineer Tucson Water, New Development Section 201 N. Stone Avenue, #2-220 P.O. Box 27210 Tucson, AZ 85726-7210 (520) 837-2106 tim.rowe@tucsonaz.gov |