Plan Review Detail
Review Status: Approved
Review Details: LAND DIVISION/SUBDIVISION v.3
Plan Number - TD-DIV-0723-00086
Review Name: LAND DIVISION/SUBDIVISION v.3
Review Status: Approved
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| CDRC Post Review Express | APPROVED | RICK Engineering Attn: Theresa Hadley 3945 E Fort Lowell Rd #111 Tucson, AZ 85712 Subject: Final Plat for (TD-DIV-0723-00086) TETON COMMONS Lots 1-6 The above referenced project has been conditionally-approved by the City Development Review Committee (CDRC) to prepare for Mayor & Council approval. Please submit six (6) weeks in advance to the next available Mayor & Council meeting, November 19, 2024. Please take the following actions and upload PDF scans of items listed. Once Zoning approves folder in 'Final Plat Package' workflow (5-10 day review), then hand deliver items to 1st floor of PDSD for us to obtain City staff's signatures: 1. Original set of executed and notarized (permanent, black ink only) Final Plat on double matte océ or photo mylar. Fill in blank for 'filed at the request of ____'. Leave Date and Time blank. 2. Title report current within the last thirty (30) days or statement from Title Company certifying the title report previously submitted is still valid. 3. Pima County Recorder’s Office now requires separate payments for recording of plats and other documents. Please provide both payments a, b, and c via separate checks or money orders a. $24.00 for the first plat sheet and $20.00 for each additional plat sheet (in other words: $20 per plat sheet plus a flat $4.00 handling fee) b. $30.00 per document for Consent to Dedicate (if applicable) c. $30.00 per document for CC&R (if applicable) The City pays to record the Assurance Agreement. If you are unsure of the fees, please call the County Recorder’s Office at 520-740-4350. Check must be pre-printed with name and address and dated within 60 days of the scheduled Mayor & Council meeting. Please make the checks payable to the Pima County Recorder. 4. Property owner(s) and consultant mailing addresses to receive notification from the City Clerk’s Office one (1) week prior to and following Mayor & Council meeting. The Final Plat, CC&R, and Assurance Agreement must be approved at the same Mayor & Council meeting. The City Development Review Committee ensures the Assurance Agreement is reviewed by the City Attorney’s Office prior to the Mayor & Council meeting. The recorded CC&R will be mailed to the address on the cover sheet. The City Clerk’s Office keeps the recorded Final Plat and Assurance Agreement. A copy of the recorded Final Plat and Assurance Agreement will be available on www.tucsonaz.gov/pro. Should you have questions, contact Linda Reid at 520-837-4940 or linda.reid@tucsonaz.gov. |
|||
| CDRC Application Completeness Express | REVIEW COMPLETED | ||||
| External Reviewers - Tucson Electric Power (TEP) | REVIEW COMPLETED | WO#T118318 City of Tucson Planning and Development Services Attn: CDRC Admin Team Dear CDRC Admin Team Subject: Development Package for Teton - Multifamily TD-DIV-0723-00086 Tucson Electric Power Company (TEP) has reviewed and approved the development plan submitted 8/30/2024. There are existing facilities within the development which are depicted upon the plan; however, at this time there do not appear to be any apparent conflicts, protect in place. Enclosed is a copy of a TEP facilities map showing the approximate location of the existing facilities. Any relocation costs will be billable to the customer. To apply for electric service, please call the New Construction department at (520) 918- 8300. Please submit a final set of plans including approved site, electric load, paving off-site improvements and irrigation plans. If available, include a PDF version of the plans. If easements are required, they will be secured by separate instrument. Should you have any easement questions, please contact our Land Resources Department, LandReviews@tep.com. Should you have any technical questions, please contact the area designer, Cruz Vega (520) 349-9850 cruzvega@tep.com Sincerely, Design Admins Design Admins Tucson Electric Power |
|||
| New Services/JOC | REVIEW COMPLETED | TD-DIV-0723-00086 - Land Division_Subdivison v3 – 345 E TETON RD 3rd Review by Tucson Water Tucson Water has no objections to the proposed subdivision or draft final plat. Any questions, comments or concerns about these comments may be directed to: Tim Rowe, P.E., Civil Engineer Tucson Water, New Development Section 201 N. Stone Avenue, #2-220 P.O. Box 27210 Tucson, AZ 85726-7210 (520) 837-2106 tim.rowe@tucsonaz.gov |