Plan Review Detail
Review Status: Requires Resubmit
Review Details: LAND DIVISION/SUBDIVISION v.1
Plan Number - TD-DIV-0626-00039
Review Name: LAND DIVISION/SUBDIVISION v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| NPPO Standard | APPROVED | Prior to development of this site a NPPP or a NPPO Waiver will be required. Please provide the appropriate Native Plant Preservation Plan or Waiver with the development package or residential building permit. Thank you. Chad Keller, PLA chad.keller@tucsonaz.gov |
|||
| Site Zoning Standard | APPROVED | ||||
| CDRC Post Review Express | PENDING ASSIGNMENT | ||||
| External Reviewers - Pima County Assessor Standard | REQUIRES RESUBMIT | Office of the Pima County Assessor 240 N. Stone Ave. Tucson, Arizona 85701 SUZANNE DROUBIE PIMA COUNTY ASSESSOR TO: City of Tucson Development Services FROM: Deanna Medlin GIS Cartographer Pima County Assessor’s Office Deanna.Medlin@pima.gov (520)724-8203 DATE: July 15, 2026 RE: Assessor’s Review and Comments Regarding: TD-DIV-0626-00039 CMS Properties Lots 1-3 1st Submittal * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * Plat meets Assessor’s Office requirements. __X___ Plat does not meet Assessor’s Office requirements. COMMENTS: THE TITLE BLOCK MUST BE IN THE LOWER RIGHT-HAND CORNER. IT MUST HAVE THE NUMBER OF LOTS OR UNITS OR BLOCKS OR ANY COMBINATION OF THESE. IT MUST HAVE THE COMMON AREAS LISTED, IF THERE ARE ANY. IT MUST HAVE THE SECTION, TOWNSHIP AND RANGE AND IF IT IS A RESUBDIVISION, IT MUST MENTION THE PLAT NAME AND THE MAP AND PLAT. *In the title block there should include the number of lots, as well as the corresponding SECTION, TOWNSHIP and RANGE. THE LOCATION MAP MUST BE IN THE UPPER RIGHT-HAND CORNER AND MUST HAVE THE SECTION, TOWNSHIP AND RANGE. THE PROJECT AREA SHOULD BE OUTLINED OR HAVE AN ARROW POINT TO IT. GENERAL NOTES MUST HAVE THE GROSS AREA OF THE SUBDIVISION, THE NUMBER OF LOTS, THE NUMBER OF MILES OF NEW ROAD, PUBLIC OR PRIVATE, EVEN IF THE NUMBER IS 0, AND THE BASIS OF BEARING. THERE MUST BE A SECTION TIE, WITH A BEARING AND DIMENSION FROM THE SECTION CORNER OR QUARTER CORNER TO THE POINT OF TIE ON THE SUBDIVISION. THE PERIMETER LINE MUST BE SOLID AND THE HEAVIEST LINE WEIGHT ON THE PLAT. THE LOT LINES AND COMMON AREA LINES MUST BE SOLID AND THE NEXT HEAVIEST. LINES FOR EROSION SETBACKS, FLOODPLAIN LINES ETC. SHOULD BE THE LIGHTEST LINE WEIGHT AND BE DASHED OR DOT-DASHED. THERE MUST BE BEARINGS AND DIMENSIONS FOR THE PERIMETER AND ALL LOT LINES AND ALL COMMON AREAS. ALL LOTS MUST BE NUMBERED AND HAVE SQUARE FOOTAGE. IF THE AREA IS TOO SMALL, THEY CAN HAVE A TABLE TO THE SIDE FOR THE SQUARE FOOTAGE. ALL HATCHING, STIPPLING, STRIPING ETC., MUST BE REMOVED IN THE FINAL PLAT, UNLESS ANOTHER AGENCY REQUIRES IT. IF SO, ALL LETTERING MUST HAVE THE HATCHING, ETC., CUT AWAY SO THEY ARE LEGIBLE. ALL STREETS MUST BE NAMED IN THE FINAL PLAT, AND HAVE DIMENSIONS, BEARINGS, AND CURVE DATA. ALL ADJACENT SUBDIVISIONS SHOULD BE NAMED, WITH MAP AND PLAT IN THE APPROPRIATE AREAS AROUND THE SUBDIVISION. OWNERSHIP PRINTED IN THE DEDICATION SECTION OR ELSEDWHERE IN THE PLAT MUST MATCH ASSESSOR DATA. *Our Assessor’s office shows current ownership as: 1523 N Rosemont LLC NOTE: THE ASSESSOR’S CURRENT INVOLVEMENT IN PROCESSING ITS MAPS TO DIGITAL FORMAT IS EXPEDITED GREATLY BY EXCHANGE OF DIGITAL DATA. IN THE COURSE OF RECORDING THIS SUBDIVISION YOUR ASSISTANCE IN PROVIDING THIS OFFICE WITH AN AUTOCAD COPY WOULD BE GREATLY APPRECIATED. AUTOCAD DWGS CAN BE SENT TO THE EMAIL ABOVE AND/OR ASRGIS@PIMA.GOV. THANK YOU FOR ANY DIGITAL DATA PREVIOUSLY SUBMITTED. |
|||
| External Reviewers - Pima County Wastewater (RWRD) Standard | REQUIRES RESUBMIT | The applicant is responsible for obtaining review and approval by Pima County, for projects involving RWRD sewers, on-site wastewater treatment facilities and public water systems https://www.pima.gov/1766/Wastewater-Reclamation. The applicant must provide an Approval letter from RWRD, prior to PDSD Approving the permit. | |||
| Site Engineering Standard | REQUIRES RESUBMIT | Site Engineering Review TD-DIV-0626-00039 1515 N ROSEMONT BL Permit Summary: Divide Parcel #121-11-102A into 3 lots Site Engineering comments are as follows: 1. Include, “Tucson” in the title blocks. 2. Provide the actual plan number, TD-DIV-0626-00039, in the lower-right near the parcel description. 3. Remove the reference to Mayor and Council under the approval section. The approval of plats is now a PDSD administrative process. 4. Address the resubmittal comments by the other reviewers. 5. Additional comments may be forthcoming depending on the content of files submitted for subsequent review cycles. *Please submit revised drawings along with a detailed response letter stating how each resubmittal comment has been addressed* To re-submit, visit the Tucson Development Center Online at: https://tdc-online.tucsonaz.gov/#/home The instructions for resubmittal can be found at: Revisions and Resubmittals Engineering Associate: Ryan Insalaco ryan.insalaco@tucsonaz.gov |
|||
| CDRC Application Completeness Express | REVIEW COMPLETED | Will let this go through review but approval block does not need to reflect Mayor and Council. Please see below for new approval block APPROVAL “I, (Marisa Stoller), Clerk of the City of Tucson, Arizona, hereby certify that this plat was approved on this ____ day of __________, 20__.” ____________________________________________ ______________ Clerk, City of Tucson Date Sequence________________ Fee_____________________ State of Arizona County of Pima I hereby certify that the instrument was filed for record at the request Of__________________________ Date________________________ Time_________________________ Witness my hand and Official Seal day and year above written. (“name of current County Recorder”), County Recorder BY___________________________ Deputy |
|||
| CDRC Review Coordinator Express | REVIEW COMPLETED | CDRC added Assessors and Addressing to the workflow. Review request email sent to Addressing and Assessors.FYI email sent to TEP, PAG, USPS, and SWG | |||
| Commercial Building Standard | REVIEW COMPLETED | ||||
| Commercial Plumbing Standard | REVIEW COMPLETED | ||||
| External Reviewers - Pima County Addressing Standard | REVIEW COMPLETED | Good morning, Pima County Addressing approves TD-DIV-0626-00039. Thank you, David Wilging Planner I - Addressing Division Pima County Development Services 201 N. Stone Avenue 1st Floor Tucson, Arizona 85701 520-724-6381 |
|||
| Fire New Construction Standard | REVIEW COMPLETED | ||||
| New Services/JOC Standard | REVIEW COMPLETED | Tucson Water has no objection to the proposed land division. Each proposed parcel meets the minimum 15-foot frontage requirement for access to public water service. Future water meters shall be coordinated with Tucson Water New Services. | |||
| OK to Submit - Engineering Fast | REVIEW COMPLETED | ||||
| OK to Submit - Zoning Fast | REVIEW COMPLETED | ||||
| Residential Building Standard | REVIEW COMPLETED |