| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| External Reviewers - Pima County Assessor Standard | PENDING ASSIGNMENT | ||||
| Site Zoning Standard | PENDING ASSIGNMENT | ||||
| Site Engineering Standard | REQUIRES RESUBMIT | Permit Activity Number: TD-DIV-0626-00038 (2nd Review) Project: Final Plat for creation of 10 separate lots Application Type: Land Division/Subdivision Location: 9915 E OLD VAIL RD Review Date: 10/22/2026 Reviewer: Marco Contreras – Engineering Associate Reviewer Contact Information: marco.contreras@tucsonaz.gov Related cases: Plan review for the above-referenced Land Division application has been completed by Site Engineering. This review was conducted for compliance with applicable land division criteria, including the City of Tucson Unified Development Code (UDC), Administrative Manual (AM), and Technical Standards Manual (TSM) sections governing plat and land split applications, subdivision standards, and all applicable site standards. The following Site Engineering comments must be addressed prior to approval of this application. To help facilitate a timely resubmittal, please provide updated plans and calculations along with a written response to each comment individually, indicating what action(s) were taken and where the change can be found on the plans. DO NOT USE revision clouds on resubmittal drawings — revision clouds paired with deltas are solely reserved for post-permit revisions. Submit your response letter and updated plan set and reports as separate files. Applicable Code Links for quick/direct reference: City of Tucson Development Code: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Codes UDC Article 8 – Land division: https://codelibrary.amlegal.com/codes/tucson/latest/tucson_az_udc/0-0-0-6428 AM 2-07.0.0 – Plat Applications: https://codelibrary.amlegal.com/codes/tucson/latest/tucson_az_udc/0-0-0-8971 AM 2-08.0.0 - Land Split Applications: https://codelibrary.amlegal.com/codes/tucson/latest/tucson_az_udc/0-0-0-9108 COT Engineering Codes: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Codes/Engineering-Codes Site Engineering Review Comments: 1. Revise the final plat to provide the following required general note: There will be no further division of lots without the expressed approval of the City of Tucson. [AM 2-07.5.8.H] 2. Title Block correction: The plat states “Being a resubdivision of a portion of block 1 phase 2 of “Old Vail Plaza,” a subdivision according to the plat recorded at sequence 2011270309.” The actual sequence # would be 20112770309. Revise accordingly 3. Clarification required regarding general note #11 – What is the intent of this note? a. After review of TD-DEV-0626-00149 – no channel is shown or proposed within lot 4 but is shown proposed on lot #8(Final plat #8, Tentative lot #7. 4. Final Site Engineering approval for this final plat application cannot be granted until the related tentative plat TD-DEV-0626-00149 is approved. |
|||
| CDRC Application Completeness Express | REVIEW COMPLETED | ||||
| External Reviewers - Pima County Wastewater (RWRD) Standard | REVIEW COMPLETED | Record P26WS00048: Sewer Layout Approval Record Status: Issued |
|||
| External Reviewers - Tucson Electric Power (TEP) Standard | REVIEW COMPLETED | Plan Number: TD-DIV-0626-00038 Plan Type: Land Division Description: Final Plat for creation of 10 separate lots Address: Yes Parcel: 14118602B Name of Subdivision: 10000 E Old Vail Site B Tucson Electric Power (TEP) has reviewed and approves the Final Plat submitted on October 21, 2026. Please call the New Construction Department at 520-918-8300 to apply for service. Submit a final set of approved plans including electrical load and offsite improvement plans to determine how TEP will serve this development. If easements are required, they will be obtained by separate instrument. Please contact me at 520-965-4030 should you have any questions. Liza Castillo Right-of-Way Consultant for Tucson Electric Power Co. Land Resources (520) 965-4030 tepdevrev@tep.com |
|||
| New Services/JOC Standard | REVIEW COMPLETED | The previous Tucson Water comment has been addressed. Tucson Water has no objection to the proposed final plat. |