Plan Review Detail
Review Status: Requires Resubmit
Review Details: LAND DIVISION/LOT SPLIT v.1
Plan Number - TD-DIV-0624-00058
Review Name: LAND DIVISION/LOT SPLIT v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| Record Documents Express | PENDING ASSIGNMENT | ||||
| Site Engineering | REQUIRES RESUBMIT | See zoning comment re: lot coverage calculations https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/permits/residential-permits/residential_plot_plan_requirements.pdf Mike Ortiz michael.ortiz@tucsonaz.gov |
|||
| Site Zoning | REQUIRES RESUBMIT | PDSD TRANSMITTAL FROM: PDSD Zoning Review PROJECT: 2758 N MONTEZUMA AV. – R-2 TD-DIV-0624-00058 Land Split (1st Review) TRANSMITTAL DATE: July 2, 2024 COMMENTS: Please resubmit revised drawings along with a detailed response letter, which states how all Zoning Review Section comments were addressed. SECTION 2-08.0.0: LAND SPLIT 2-08.5.0 CONTENT REQUIREMENTS 1. COMMENT: 2-08.5.G – Provide a lot coverage calculation for Parcel 24-A that meets the requirements of UDC Article 6.4.3 and the example shown on the Residential Plot Plan Requirements found at: https://www.tucsonaz.gov/files/pdsd/forms/Residential_Plot_Plan_Requirements.pdf. If you have any questions about this transmittal, please contact Nicholas Martell at Nocholas.Martell@tucsonaz.gov. |
|||
| TW New Development Review | REQUIRES RESUBMIT | TD-DIV-0624-00058 - Land Division_Land Split_Lot Split v1 – 2758 N MONTEZUMA AV Tucson Water has the following comments regarding the proposed Land Split / Lot Split. 1. Tucson Water’s Remote Meter Policy No. IV-B.08, Eff. 07/14/2009 requires each lot to have its own water meter. It also prohibits the private water line from a water meter to a building on one lot from lying on, or crossing, any other lot. 2. The existing water meter serving the existing building on New Lot 24-A, is located in New Lot 24-B’s frontage onto Montezuma Avenue where an existing 6” public water main is located. To comply with Tucson Water’s Remote Meter Policy the existing water meter may not continue to serve the existing building on New Lot 24-A after the lot split is complete. It may only be used to serve New Lot 24-B. 3. A new water meter will need to be obtained for New Lot 24-A, and it must be in New Lot 24-A’s frontage onto either Montezuma Avenue, or Glenn Street where an existing 8” water main is located. 4. The correct internet address for the Supplemental Residential Plot Plan Requirements referenced by the Zoning review is https://www.tucsonaz.gov/Departments/Planning-Development-Services/Building-Safety/Plan-Examples/Plot-Plan-Example. Please note that the locations of the utility lines for water , sewer, electric and gas must be shown. 5. Please submit a supplemental residential plot plan that shows the new water meter and new private water lines to the existing building on New Lot 24-A, and the existing water meter being retained to serve New Lot 24-B. 6. Any questions, comments or concerns about these comments may be directed to: Tim Rowe, P.E., Civil Engineer Tucson Water, New Development Section 201 N. Stone Avenue, #2-220 P.O. Box 27210 Tucson, AZ 85726-7210 (520) 837-2106 tim.rowe@tucsonaz.gov |
|||
| CDRC Application Completeness Express | REVIEW COMPLETED | ||||
| Commercial Building | REVIEW COMPLETED | Not commercial, please see Residential Building comment. | |||
| Commercial Plumbing | REVIEW COMPLETED | Not commercial, please see Residential Building comment. | |||
| Residential Building | REVIEW COMPLETED |