Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Plan Number: TD-DIV-0624-00053
Parcel: 13821007A

Review Status: Requires Resubmit

Review Details: LAND DIVISION/SUBDIVISION v.2

Plan Number - TD-DIV-0624-00053
Review Name: LAND DIVISION/SUBDIVISION v.2
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
External Reviewers - Pima County Wastewater (RWRD) APPROVED Record P24WS00104:
Sewer Layout Approval
Record Status: Issued
Site Zoning APPROVED
CDRC Post Review Express PENDING ASSIGNMENT
External Reviewers - Pima County Assessor REQUIRES RESUBMIT Office of the Pima County Assessor
240 N. Stone Ave. Tucson, Arizona 85701
SUZANNE DROUBIE
PIMA COUNTY ASSESSOR
TO: City of Tucson Development Services
FROM: Karl Christensen
GIS Analyst II
Pima County Assessor’s Office
Karl.Christensen@pima.gov
(520)724-3125
DATE: November 25, 2024
RE: Assessor’s Review and Comments Regarding: (SUBMITTAL 2)
TD-DIV-0624-00053 – SAN FERNANDO HEIGHTS - FINAL PLAT
* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * *
_ Plat meets Assessor’s Office requirements.
__X___ Plat does not meet Assessor’s Office requirements.
COMMENTS:
It appears the Assessor’s Office has been requested to review this Activity a
second time after reviewing and approving a previous submittal. However, I can
not find the previous submittal document reviewed, and the staff member that
conducted the previous review no longer works for this Office. Issues with our
requirements in this Second Submittal have been found, so I will proceed with
this Second Submittal review and rescind our Office’s previous approval.
* [Boilerplate Text] The perimeter line must be solid and the heaviest
lineweight on the plat. The lot lines and common area lines must be solid and
the next heaviest. Lines for erosion setbacks, floodplain lines etc. should be
the lightest lineweight and be dashed or dot-dashed.
* Please provide the square footage area for Common Area “A”. It is recognized
that this is a street, but because it is a private street the Assessor’s Office
will be assigning an APN and valuing it as a parcel, so an area will be needed.
* Please confirm in your Comment Response that all Curve segments in this
plat are tangent to adjoining Lines or Reverse/Compound Curve segments. Lack
of Radial Bearings and/or Chord dimensions implies by common platting
practice that all Curves are tangent, but unexpected Curve radii found in the
Curve Table call this implication into question. If any Curve segments are
not tangent, please provide in the plat either Radial bearings or Chord
dimensions for those Curve segments.
* There are a number of missing bearings/dimensions in this plat. Please make
sure there is sufficient bearing/dimension information to be able to traverse
the Subdivision perimeter, as well as each individual Lot. Some of the missing
bearings/dimensions are as follows (this may not be a comprehensive finding):
- Bearing(s) for the East line of the Subdivision (ie: The East lines of Lots
15, 5, 6, 7, & 8).
- Bearing(s) for the South line of the Subdivision (ie: The South lines of Lots
8, 9, & 10).
- Bearing for the West line of the Subdivision (ie: The West line of Lot 10).
- Bearing(s) for the South line of the Subdivision (ie: The South lines of
Lots 11, 12, 13 & C.A. ‘C’).
- Bearing for the West line of Lot 13 coincident with the East line of C.A.
‘C’.
- Bearing(s) for the West line of the Subdivision (ie: The West lines of C.A.
‘A’, ‘B’, & ‘C’), as well as the Distance for the West line of C.A. ‘A’.
- Bearing(s) for the North line of the Subdivision (ie: The North lines of
Lots 1, 2, & C.A. ‘B’).
- Bearing(s) for the West line of the Subdivision (ie: The West lines of Lots
2 & 14).
- Bearing and Distance for the East line of Lot 14 (West of the NorthEast
excluded portion of 04/040).
- Bearing(s) for the North lines of Lots 14 & 15 (South of the NorthEast
excluded portion of 04/040).
- Bearing and Distance for the West line of Lot 15 (East of the NorthEast
excluded portion of 04/040).
- Bearing(s) for the South lines of Lots 14 & 15 coincident with the North
lines of Lots 2, 3, 4, & 5.
- The total Distance of the South lines of Lots 14 & 15 coincident with the
North lines of Lots 2, 3, 4, & 5 -and/or- the missing line segment Distances
of the North lines of Lots 4 & 5.
- Bearing for the 12.02’ East line of Lot 11 coincident with C.A. ‘A’ -and/ora 1/2 R/W offset dimension from the street centerline (if parallel).
- Bearing for the 26.60’ West line of Lot 7 coincident with C.A. ‘A’.
NOTE: THE ASSESSOR’S CURRENT INVOLVEMENT IN PROCESSING ITS MAPS TO DIGITAL
FORMAT IS EXPEDITED GREATLY BY EXCHANGE OF DIGITAL DATA. IN THE COURSE OF
RECORDING THIS PLAT YOUR ASSISTANCE IN PROVIDING THIS OFFICE WITH AN AUTOCAD
COPY WOULD BE GREATLY APPRECIATED. AUTOCAD DWGS CAN BE SENT TO THE EMAIL ABOVE
AND/OR ASRGIS@PIMA.GOV. THANK YOU FOR ANY DIGITAL DATA PREVIOUSLY SUBMITTED.
CDRC Application Completeness Express REVIEW COMPLETED
External Reviewers - Pima County Addressing REVIEW COMPLETED Good morning,



Pima County Addressing approves TD-DIV-0624-00053 San Fernando Heights Residential Subdivision.
External Reviewers - Tucson Airport Authority REVIEW COMPLETED November 21, 2024
Planning and Development Services
City of Tucson
201 North Stone Avenue
Tucson, AZ. 85701
RE: TD-DIV-0624-00053, 2
nd Submittal, San Fernando Heights Residential Subdivision / 6935 S
San Fernando Rd, Tucson, AZ 85756, Received October 29, 2024
To whom this may concern,
Thank you for the opportunity to comment on TD-DIV-0624-00053, 2
nd Submittal, the
development plan for a 15 Lot Subdivision for future residential uses at 6935 S San Fernando
Rd. This development is located in the N.E. quarter of the S.W. quarter of Section 13, Township
15S, Range 13E, of the Gila and Salt River Meridian. The development site occupies parcel
number 138-21-007A, covers approximately 3.126 ± acres, and is zoned as Residence Zone 1
(R-1). The nearest major roadway intersection is West Elvira Road and San Fernando Avenue,
approximately 200 feet to the northwest of the subject development.
This site does lie within the Tucson International Airport avigation easement requirements and
public disclosure area, FAA traffic pattern airspace, and FAA Part 77 airspace.
The Tucson Airport approves the 2nd submittal of this project and is not requiring a resubmit of
this project.
Please do not hesitate to contact me if you have any questions or concerns regarding this
comment letter. I can be reached by email at srobidoux@flytucson.com or by telephone at 520-
573-4811.
Respectfully,
Scott Robidoux, C.M.
Manager of Planning
External Reviewers - Tucson Electric Power (TEP) REVIEW COMPLETED Greetings,



Tucson Electric Power Co. (TEP) has reviewed the plans submitted on October 29th, 2024, and has no objections. The customer is responsible for compliance with City Ordinances. Please keep in mind that a jurisdictional permit for any work on a public road right of way where applicable. Easements are required for TEP facilities if not appropriately recorded on the final plat. They will need to be obtained by a separate instrument.





Respectfully,

Tucson Electric Power Co.

Land Resources Department
TW New Development Review REVIEW COMPLETED TD-DIV-0624-00053 - Land Division_Subdivison v2 – 6935 S SAN FERNANDO RD

Tucson Water has no objections to the proposed subdivision of this property or the draft final plat submitted on 09/27/2024 by Oracle Engineering.

Any questions, comments or concerns about these comments may be directed to:

Tim Rowe, P.E., Civil Engineer
Tucson Water, New Development Section
201 N. Stone Avenue, #2-220
P.O. Box 27210
Tucson, AZ 85726-7210
(520) 837-2106
tim.rowe@tucsonaz.gov