Plan Review Detail
Review Status: Requires Resubmit
Review Details: LAND DIVISION/LOT SPLIT v.1
Plan Number - TD-DIV-0524-00051
Review Name: LAND DIVISION/LOT SPLIT v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| Commercial Plumbing | APPROVED | ||||
| Site Engineering | APPROVED | ||||
| Residential Building | NOT REQUIRED | Not a residential property. | |||
| Record Documents Express | PENDING ASSIGNMENT | ||||
| Commercial Building | REQUIRES RESUBMIT | Please submit your revised documents along with a detailed response letter, which states how all Building Review Section comments were addressed. 1. Lot 1: Please amend plans to show the Existing Exterior Wall (EEW), adjacent to the new lot line, meets the fire-resistance rating requirements for exterior walls based on a fire separation distance (FSD) of less than 5 feet. Additionally, provide the same information for Conex boxes, or move them to increase the FSD to meet the requirements in 2018 IBC Table 602. Provide the following information. 2018 IBC 107.2.1 A. Occupancy of both the existing building and the Conex boxes. 2018 IBC 302.1 B. Construction Type and fire resistance rating of both the existing building (EEW) and the Conex boxes. 2018 IBC Section 601, 704 and Table 601. C. Provide a section and elevation drawing of the EEW to showing it meets the requirements of 2018 IBC Section 705 and Table 705.8 For example, show parapet height of EEW, fire resistive rating, no openings, etc. 2018 IBC 107.2.1 Mark Masek Plans Examiner – Building Safety Planning and Development Services | City of Tucson main 520.837.4994 email mark.masek@tucsonaz.gov |
|||
| Site Zoning | REQUIRES RESUBMIT | PDSD TRANSMITTAL FROM: PDSD Zoning Review PROJECT: 3445 S Country Club Rd. Tucson, AZ. 85713 TD-DIV-0524-00051 Land Split (1st Review) TRANSMITTAL DATE: June 06, 2024 COMMENTS: Please resubmit revised drawings along with a detailed response letter, which states how all Zoning Review Section comments were addressed. SECTION 2-08.0.0: LAND SPLIT 2-08.2.0 CONTENT REQUIREMENTS 1. COMMENT: 2-08.5.E – Per UDC Article 6.6.2.b An accessory building shall be built only on a lot occupied by a principal building or use. That said, the "Metal Canopy" structure shown on Lot 2 is considered and accessory building and will need to be removed prior to approval of this plan. If the canopy is to be removed notate "To Be Removed" on the site plan with the next submittal. 2. COMMENT: Aerial imagery shows structures located on the north side of Lot 2 that are not shown on the provided site plan. Clarify if those structures are no longer on the property. If the structures are still on the property they will also have to be removed (per Comment 1). If you have any questions about this transmittal, please contact Nathan Herrera at Nathan.Herrera@tucsonaz.gov. |
|||
| CDRC Application Completeness Express | REVIEW COMPLETED | ||||
| TW New Development Review | REVIEW COMPLETED | TD-DIV-0524-00051 - Land Division_Land Split_Lot Split v1 – 3445 S COUNTRY CLUB RD 1. Tucson Water has no objections to the proposed Land Split / Lot Split. 2. Any questions, comments or concerns about these comments may be directed to: Tim Rowe, P.E., Civil Engineer Tucson Water, New Development Section 201 N. Stone Avenue, #2-220 P.O. Box 27210 Tucson, AZ 85726-7210 (520) 837-2106 tim.rowe@tucsonaz.gov |