Plan Review Detail
Review Status: Requires Resubmit
Review Details: LAND DIVISION/LOT SPLIT v.2
Plan Number - TD-DIV-0523-00066
Review Name: LAND DIVISION/LOT SPLIT v.2
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| Site Engineering | APPROVED | ||||
| Site Zoning | APPROVED | ||||
| Record Documents Express | PENDING ASSIGNMENT | ||||
| Residential Building | REQUIRES RESUBMIT | Provide the permit numbers for altering each dwelling showing alterations of each dwelling for 2018 IRC compliance as a condition for the proposed lot split. Provide a complete floor plan showing walls within 3-foot of the proposed property line with not less than one-hour fire-resistive construction on each side of the property line. Show compliance with R302.1 (City of Tucson Amended) by providing a section detail of materials prescribed in IBC Table 721.1(2), Items 15-1.1 to 16-1.3. 1. Also, show utility alterations for removing one dwelling utility from the other property. including the water and sewer lines. Each dwelling requires an accessible electrical service panel. |
|||
| CDRC Application Completeness Express | REVIEW COMPLETED |