Plan Review Detail
Review Status: Requires Resubmit
Review Details: LAND DIVISION/LOT SPLIT v.2
Plan Number - TD-DIV-0426-00027
Review Name: LAND DIVISION/LOT SPLIT v.2
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| Site Engineering Fast | APPROVED | ||||
| Site Zoning Fast | APPROVED | ||||
| Record Documents Express | PENDING ASSIGNMENT | ||||
| Commercial Plumbing Fast | REQUIRES RESUBMIT | This lot split cannot be approved until the outstanding comments have been successfully addressed. If you have any questions about this review comment, I can be reached at Robert.Sherry@tucsonaz.gov. Initial comments: 1. Please show the location of the private sewer line serving each dwelling. Reference: Section 107.2.1, IBC 2024. 2. Please show the location of the water supply line serving each dwelling. Reference: Section 107.2.1, IBC 2024. a. Note: Tucson Water’s Remote Meter Policy No. IV-B.08, Eff. 07/14/2009 requires all of the following: i. Each lot must have its own water meter. ii. The water meter for any given lot must lie within that lot’s frontage onto a public street, private street, or utility easement that contains an existing water main that can serve that lot. iii. The private water line from a water meter to building must lie on just one lot. The private water line from a water meter to a building may not encroach into, or cross a second lot, even in a private water easement. The private water line may not cross any existing or proposed lot line. |
|||
| Residential Building Fast | REQUIRES RESUBMIT | TD-DIV-0426-00027 PROVIDE A COMPLETE PLAN SET showing all proposed alterations to the building with 2024 IRC code compliance. Provide a response letter addressing each comment with location of change on the plans. Submit separate letter and plan set files. SITE PLAN REQUIREMENTS: 1. Show the new location of water, gas and electric lines serving the dwelling without crossing the adjacent property, R106.1.1. The lot split may require re-setting utility lines from the adjacent property. https://www.tucsonaz.gov/Departments/Planning-Development-Services/Permits/Plan-Examples 2. Show the location of a sewer line for each dwelling from the building to the HCS without crossing the adjacent property, R106.1.1. This may require a sewer line replacement including a new HSC processed with Pima County Wastewater Management and filing a new utility easement with The Pima County Recorder. https://www.pima.gov/1766/Wastewater-Reclamation 3. Show the location of the water supply line for each dwelling from the building to a separate water meter without crossing the adjacent property, R106.1.1. This may require a water line replacement including a new meter processed with the Tucson Water Department and filing a new utility easement with The Pima County Recorder 4. Show the location of the electrical line and identify as overhead or underground, R106.1.1. New or altered lines require coordination with Tucson Electric Power. https://www.tep.com/construction-applications/#apply 5. Show the dwelling structures located within the required setback dimensions from the proposed property line. A dwelling may not extend to a point closer than 3 feet from the proposed property line without fire rated protection for fire spread, R302.1 (City of Tucson Amended). If you have any questions, please contact: Kenneth.VanKarsen@tucsonaz.gov City of Tucson Residential Building Safety |
|||
| CDRC Application Completeness Express | REVIEW COMPLETED | ||||
| TW New Development Review Fast | REVIEW COMPLETED | Tucson Water has no objection to the proposed land division for the parcel located at 104 W District St, Parcel No. 12007212A. Based on Tucson Water records, the existing parcel is currently served by an existing 5/8-inch water meter, Naviline Meter No. 16082272. If the owner will keep the existing water meter after the recorded lot split, or if any account/service information needs to be updated, please contact Tucson Water to coordinate the required updates. For the second parcel, the potential water main to tie the proposed water meter into is the existing 8-inch CA water main along W District St, PN 129-1980. After the land division has been recorded, the additional water meter may be requested through Tucson Water New Services. Please coordinate with Tucson Water New Services for the proposed meter location and any applicable connection requirements. |