Plan Review Detail
Review Status: Requires Resubmit
Review Details: LAND DIVISION/LOT SPLIT v.1
Plan Number - TD-DIV-0425-00047
Review Name: LAND DIVISION/LOT SPLIT v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| Commercial Plumbing Fast | APPROVED | ||||
| Site Zoning Fast | APPROVED | ||||
| Record Documents Express | PENDING ASSIGNMENT | ||||
| Site Engineering Fast | REQUIRES RESUBMIT | 1. Please address Tucson Water comments relating to utility easements on this property. 2. Please clarify if the cooling towers on located on the building within proposed parcel 2 service the commercial building that they are on, or the tower located on proposed parcel 1. If they service parcel 1, please provide access, maintenance, and utility easement. Joshua Garcia joshua.garcia@tucsonaz.gov |
|||
| TW New Development Review Fast | REQUIRES RESUBMIT | TD-DIV-0425-00047 - Land Division_Lot Split v1 – 1475 N ORACLE RD Tucson Water has the following comments about the proposed Land Split / Lot Split: 1. Per Tucson Water’s SE021413 valve map and Tucson Water’s GIS system there is an existing 8” water main constructed per work order number WO 4608 and an existing 4” fire service constructed per work order number BWO 37767 on the larger of the two proposed parcels. 2. Tucson Water has no record of this existing 8” water main and existing 4” fire service being within a water or public utility easement. Please provide a Title Report for the parent parcel that lists all known easements on the parent property. 3. If this existing 8” water main and existing 4” fire service is not within a known water or public utility easement, such an easement will need to be granted by the owner of the parent parcel, before Tucson Water can approve this proposed lot split. Any questions, comments or concerns about these comments may be directed to: Tim Rowe, P.E., Civil Engineer Tucson Water, New Development Section 201 N. Stone Avenue, #2-220 P.O. Box 27210 Tucson, AZ 85726-7210 (520) 837-2106 tim.rowe@tucsonaz.gov |
|||
| CDRC Application Completeness Express | REVIEW COMPLETED | ||||
| Commercial Building Fast | REVIEW COMPLETED | 1. SOUTH AND WEST building walls. Ensure the property line is located such that the Fire Separation Distance is met per IBC Table 602. Otherwise, a one hour fire rating on the existing exterior walls maybe required. Existing doors and windows may not be allowed per IBC 705.8 2. Show the building on the drawing and indicate the distance from the property lines. |
|||
| Residential Building Fast | REVIEW COMPLETED |