Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

The login landing page when selecting 'View' is still occurring and is still pending further investigation. 

Review Status: Requires Resubmit

Review Details: LAND DIVISION/LOT SPLIT v.1

Plan Number - TD-DIV-0324-00030
Review Name: LAND DIVISION/LOT SPLIT v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
Commercial Plumbing APPROVED
Record Documents Express PENDING ASSIGNMENT
Site Engineering REQUIRES RESUBMIT See zoning comment. Provide a supplementary plot plan.

Lianne Evans
lianne.evans@tucsonaz.gov
Site Zoning REQUIRES RESUBMIT PDSD TRANSMITTAL

FROM: PDSD Zoning Review

PROJECT: 844 W ALTURAS ST.– R-1
TD-DIV-0324-00030
Land Split (1st Review)

TRANSMITTAL DATE: April 5, 2024

SECTION 2-08.0.0: LAND SPLIT

2-08.2.0 CONTENT REQUIREMENTS

1. COMMENT: 2-08.5.E – For both proposed parcels provide a supplemental Residential Plot Plan that meets the requirements found at: https://www.tucsonaz.gov/files/pdsd/forms/Residential_Plot_Plan_Requirements.pdf, The plot plan shall show all structures that are on this site along with perimeter yard setbacks to the proposed property line and a lot coverage calculation. Required perimeter yard setbacks are based on a measurement from design grade to the highest point of the exterior wall UDC Article 6.4.5.B & Figure 6.4.5-A. The minimum setback is the greater of six (6) feet, or two-thirds (2/3) the height of the structure’s wall facing each interior property line (Table 6.3-2.A). If any of the proposed setbacks to not meet the minimum additional comments maybe forth coming.

If you have any questions about this transmittal, please contact Nicholas Martell at Nicholas.Martell@tucsonaz.gov.
TW New Development Review REQUIRES RESUBMIT TD-DIV-0324-00030 - Land Division_Land Split_Lot Split v1 – 844 W ALTURAS ST

1. Tucson Water’s records indicate APN 10708228A and APN 10708229A are currently using a single water meter. This is no longer allowed. Parcel 1 and Parcel 2 will need to have separate water meters.

2. The water meter for Parcel 1 must be in Parcel 1’s frontage onto Alturas Street. And the water meter for Parcel 2 must be in Parcel 2’s frontage onto Alturas Street. No water service lines may cross the common lot line that separates the two new parcels from each other.

3. Show the existing and proposed new water meters and the private water service lines between those meters to the existing buildings on the supplemental Residential Plot Plans that the Zoning Reviewer has required.

4. Any questions, comments or concerns about these comments may be directed to:

Tim Rowe, P.E., Civil Engineer
Tucson Water, New Development Section
201 N. Stone Avenue, #2-220
P.O. Box 27210
Tucson, AZ 85726-7210
(520) 837-2106
tim.rowe@tucsonaz.gov
CDRC Application Completeness Express REVIEW COMPLETED
Commercial Building REVIEW COMPLETED
Residential Building REVIEW COMPLETED