Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Plan Number: TD-DIV-0226-00013
Parcel: 11918087A

Address:
3660 S 16TH AV

Review Status: Requires Resubmit

Review Details: LAND DIVISION/SUBDIVISION v.3

Plan Number - TD-DIV-0226-00013
Review Name: LAND DIVISION/SUBDIVISION v.3
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
Site Engineering Standard APPROVED
Site Zoning Standard APPROVED
NPPO Standard NOT REQUIRED This site has been previously developed and is void of protected native plants. An NPPO is not required for this land division.

Thank you.
Chad Keller, PLA
chad.keller@tucsonaz.gov
CDRC Post Review Express PENDING ASSIGNMENT
External Reviewers - Pima County Assessor Standard REQUIRES RESUBMIT Office of the Pima County Assessor
240 N STONE AVENUE
Tucson, Arizona 85701
SUZANNE DROUBIE
ASSESSOR
TO: City of Tucson
Planning and Development Services Department
FROM: Jayden Fenske
GIS Analyst I
Pima County Assessor’s Office
Jayden.Fenske@pima.gov
520-724-7414

DATE: 4/7/2026

RE: Assessor’s Review and Comments Regarding: TD-DIV-0226-
00013 – REPLAT FOR SANTA CRUZ PLAZA – Submittal 1


* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * *
Plat meets Assessor’s Office requirements.
___X___ Plat does not meet Assessor’s Office requirements.
COMMENTS:
See below for the full list of generalized requirements the Assessor’s Office
review for, with items in this plat needing improvement in bold and the sub
bullet points.
• The title block must be in the lower right-hand corner. It must have
the number of lots or units or blocks, or any combination of these. It
must have the common areas listed, if there are any. It must have the
section, township, and range, and if it is a resubdivision, it must
mention the plat name and the map and plat.
• The location map must be in the upper right-hand corner and must have
the section, township, and range. The project area should be outlined
or have an arrow pointing to it.
• General notes must include the gross area of the subdivision, the
number of lots, the number of miles of new road (public or private),
even if the number is 0, and the basis of bearing.
• There must be a section tie, with a bearing and dimension from the
section corner or quarter corner to the point of tie on the
subdivision.
• The perimeter line must be solid and the heaviest line weight on the
plat. The lot lines and common area lines must be solid and the next
heaviest. Lines for erosion setbacks, floodplain lines, etc., should be
the lightest line weight and be dashed or dot-dashed.
• There must be approximate dimensions for the perimeter and all lot
lines and all common areas.
• All lots must be numbered and have square footage. If the area is too
small, a table to the side can be used for the square footage.
o Please list the square footage of each individual lot.
• All hatching, stippling, striping, etc., must be removed in the final
plat, unless another agency requires it. If so, all lettering must have
the hatching, etc., cut away so it is legible.
• All streets must be named (sometimes they aren’t in the tentative) in
the final plat, and have dimensions, bearings, and curve data.
• All adjacent subdivisions should be named, with map and plat in the
appropriate areas around the subdivision.
o The properties north of this subdivision, shown as APN 119-18-
039F & 119-18-089A, do not list the subdivision name and map and
plat information. Please review and revise.
• Name listed on the dedication line matches with owner according to
Assessor records.
a. For reference, our records show that property ownership of parcel
119-18-087A is held under “KHATOON LLC” which matches with name
listed on the dedication section of this. Upon recordation, these
names must match or we may be unable to process the plat.
NOTE: THE ASSESSOR’S CURRENT INVOLVEMENT IN PROCESSING ITS MAPS TO DIGITAL
FORMAT IS EXPEDITED GREATLY BY EXCHANGE OF DIGITAL DATA. IN THE COURSE OF
RECORDING THIS SUBDIVISION PLAT, YOUR ASSISTANCE IN PROVIDING THIS OFFICE WITH
AN AUTOCAD COPY WOULD BE GREATLY APPRECIATED. AUTOCAD DWGS CAN BE SENT TO THE
EMAIL ABOVE AND/OR ASRGIS@PIMA.GOV. THANK YOU FOR ANY DIGITAL DATA PREVIOUSLY
SUBMITTED.
External Reviewers - Pima County Wastewater (RWRD) Standard REQUIRES RESUBMIT The applicant is responsible for obtaining review and approval by Pima County, for projects involving RWRD sewers, on-site wastewater treatment facilities and public water systems https://www.pima.gov/1766/Wastewater-Reclamation. The applicant must provide an Approval letter from RWRD, prior to PDSD Approving the permit.
CDRC Application Completeness Express REVIEW COMPLETED
CDRC Review Coordinator Express REVIEW COMPLETED CDRC added Addressing, Assessors, TAA, ADOT, TEP, PAG, USPS, and SWG to the workflow. Review request email sent to Addressing, Assessors, TAA, ADOT, TEP. FYI email sent to PAG, USPS, SWG.
Commercial Building Standard REVIEW COMPLETED
Commercial Plumbing Standard REVIEW COMPLETED
Entitlements Standard REVIEW COMPLETED
External Reviewers - Arizona Department of Transportation (ADOT) Standard REVIEW COMPLETED ADOT has no comments.

Thanks, Rick Freije
External Reviewers - Pima Association of Governments Standard REVIEW COMPLETED CDRC sent FYI email sent to PAG, USPS, SWG. No further action is required
External Reviewers - Pima County Addressing Standard REVIEW COMPLETED Good afternoon,

Pima County Addressing approves of TD-DIV-0226-00013. Please be aware that the APN numbers for lots 9 and 1 are missing a 0 on the end of the APN.



Thank you,









David Wilging

Planner I - Addressing Division

Pima County Development Services

201 N. Stone Avenue 1st Floor

Tucson, Arizona 85701

520-724-6381
External Reviewers - Southwest Gas Standard REVIEW COMPLETED CDRC sent FYI email sent to PAG, USPS, SWG. No further action is required
External Reviewers - Tucson Airport Authority Standard REVIEW COMPLETED March 29, 2026
Planning and Development Services
City of Tucson
201 North Stone Avenue
Tucson, AZ. 85701
RE: TD-DIV-0226-00013, 1st Submittal, Replat for Santa Cruz Plaza - Lot 8 / 3660 S. 16th Av,
Tucson, AZ. 85713, Received March 13, 2026
To whom this may concern,
Thank you for the opportunity to comment on TD-DIV-0226-00013, 1st Submittal, a subdivision
plan of an existing commercial use at 3660 S 16th Ave. This development is located in the S.W.
quarter of the S.E. quarter of Section 26, Township 14S, Range 13E, of the Gila and Salt River
Meridian. The development site occupies parcel numbers 119-18-087A, covers approximately
6.67 ± acres, and is zoned as Commercial 2 Zone (C-2). The nearest major roadway
intersection is Interstate 19 and West Ajo Way, approximately 800 feet to the southwest of the
subject development.
This site does lie within the Tucson International Airport avigation easement requirements and
public disclosure area, FAA traffic pattern airspace, and FAA Part 77 airspace.
The Tucson Airport Authority approves the 1st submittal of this project and is not requiring a
resubmittal of this project.
Please do not hesitate to contact me if you have any questions or concerns regarding this
comment letter. I can be reached by email at srobidoux@flytucson.com or by telephone at 520-
573-4811.
Respectfully,
Scott Robidoux, C.M.
Manager of Planning
cc file
External Reviewers - Tucson Electric Power (TEP) Standard REVIEW COMPLETED Tucson Electric Power Co. (TEP) has reviewed and approves the Final Plat for Santa Cruz Plaza, Lot 8, dated March 9, 2026.

Costs for removal or relocation of existing electrical facilities, if required, will be billable to the developer. Should additional easements be required for new development within the platted area, they will be obtained by separate instrument.



If you have any questions, please feel free to contact me at 520-965-4030.



Thank you,



Liza Castillo

Right-of-Way Consultant for

Tucson Electric Power Co.

Land Resources

(520) 965-4030

tepdevrev@tep.com
External Reviewers - United States Postal Service (USPS) Standard REVIEW COMPLETED CDRC sent FYI email sent to PAG, USPS, SWG. No further action is required
Fire New Construction Standard REVIEW COMPLETED
New Services/JOC Standard REVIEW COMPLETED No comments at this time. There is no observable impact on the existing potable water distribution main.
OK to Submit - Engineering Fast REVIEW COMPLETED
OK to Submit - Zoning Fast REVIEW COMPLETED
Residential Building Standard REVIEW COMPLETED