Review Status: Requires Resubmit

Review Details: LAND DIVISION/LOT SPLIT v.2

Plan Number - TD-DIV-0226-00010
Review Name: LAND DIVISION/LOT SPLIT v.2
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
Site Engineering Fast APPROVED
Record Documents Express PENDING ASSIGNMENT
Site Zoning Fast REQUIRES RESUBMIT CDRC TRANSMITTAL

TO: Development Services Department
Plans Coordination Office

FROM: Loran Shamis
PDSD Zoning Review Section

PROJECT: Lot line adjustment of APN 111030720 & 0710
Lot Line Reconfiguration (1st Review)
TD-DIV-0226-00010

TRANSMITTAL DATE: April 8, 2026

DUE DATE: April 7, 2026

COMMENTS: Please resubmit revised drawings along a detailed response letter, which states how all Zoning Review Section comments were addressed.

This plan has been reviewed for compliance with the Unified Development Code (UDC) 8.3.1 Land Split and Administrative Manual (AM) Section 2-08. Also compliance with applicable development criteria for the proposed or existing use as listed in the City of Tucson Uniform Development Code (UDC) and the UDC Technical Standards Manual (TSM).

2-08.5.0 CONTENT REQUIREMENTS
The drawing showing the proposed land split shall include the following:


1. COMMENT: The existing shed in the northeast corner of proposed lot 111-03-0720 is not meeting the minimum required setback to the property line to the north. The minimum required setback for residential use adjacent to a nonresidential zone is 5 feet from the property line per UDC Table 6.3-4.A. Per UDC 6.6.2.D, a detached accessory structure may be built to a parcel line with the consent of the adjoining property owner.

Either relocate the shed to comply with the minimum required setback or provide the following statement along with the signature of the property owner of 3129 E Greenlee Rd on the site plan:

My name is _____ and I am the owner of the property located at 3129 E Greenlee Rd. I have reviewed the site plan and I have no objection to structure being located 2.85’ from the property line as depicted on the site plan.
Signature: ________
Date: ____________

2. COMMENT: Provide a lot coverage calculations for APN 111030720. Per UDC Table 6.3-4.A, the maximum permitted lot coverage for residential uses in the C-1 zone is 75%. The lot coverage is the area of a lot covered by buildings, storage areas, and vehicular use areas. For specific application standards, refer to UDC 6.4.3.


If you have any questions about this transmittal, Contact Loran Shamis at Loran.Shamis@tucsonaz.gov or (520)-837-2242.

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised supplemental site plan.
CDRC Application Completeness Express REVIEW COMPLETED