Plan Review Detail
Review Status: Requires Resubmit
Review Details: LAND DIVISION/LOT SPLIT v.1
Plan Number - TD-DIV-0225-00028
Review Name: LAND DIVISION/LOT SPLIT v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| Record Documents Express | PENDING ASSIGNMENT | ||||
| Commercial Plumbing Fast | REQUIRES RESUBMIT | 1. Show the location of the proposed connection to the public sewer system for each parcel 2. Show the source of water service for parcel 1. |
|||
| Site Engineering Fast | REQUIRES RESUBMIT | 1. See zoning's comments Stephen Blood (520) 837-4958 Stephen.blood@tucsonaz.gov |
|||
| Site Zoning Fast | REQUIRES RESUBMIT | PDSD TRANSMITTAL FROM: PDSD Zoning Review PROJECT: 335 S CALLE DE LA AZUCENA. – R-1 zone TD-DIV-0225-00028 Land Split (1st Review) TRANSMITTAL DATE: February 28, 2025 COMMENTS: Resubmit revised drawings along with a detailed response letter, which states how all Zoning Review Section comments were addressed. SECTION 2-08.0.0: LAND SPLIT 2-08.5.0 CONTENT REQUIREMENTS 1. COMMENT: 2-08.5.E – Per UDC Article 6.6.2.B An accessory building shall be built only on a lot occupied by a principal building or use. That said, the garage shown on parcel 2 is not allowed on a lot by itself. Either 1) A demo permit will need to be submitted and approved, 2) A Board of Adjustment for Variance will need to be submitted and approve, or 3) A permit for a single family residence on parcel 2 will need to be submitted and approved, prior to approval of this land split. 2. COMMENT: 2-08.5.F – There is an existing shed shown on parcel 1 near the northwest corner of parcel 2, provide the height and a setback dimension from the shed to the adjacent property line. As it does not appear that the shed will meet the minimum 6’-0” setback, UDC Table 6.3-2.A at a minimum a neighbors setback waiver is required. As technically the current owner will own both parcel they can sign the waive. To secure this neighbor setback waiver the following statement must be provided on the plot plan and be signed and dated by the adjacent property owner(s): My Name is____________________ and I am the owner of the property located at_______________________. I have reviewed the site plan and I have no objection to structure being located or constructed________ feet from the property line as depicted on the site plan. Signature: _____________________________ Date: _________________________________ The Unified Development Code (UDC) can be found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Codes/Zoning-Code. If you have any questions about this transmittal, please contact Zone1.desk@tucsonaz.gov. |
|||
| TW New Development Review Fast | REQUIRES RESUBMIT | TD-DIV-0225-00028 - Land Division_Lot Split v1 – 335 S CALLE DE LA AZUCENA Tucson Water has the following comments about the proposed Land Split / Lot Split: 1. This lot split does not comply with the following requirements of Tucson Water’s Remote Meter Policy No. IV-B.08, Eff. 07/14/2009 in the following ways: a. Proposed Parcel 2 does not have a minimum of 15’ of real property frontage onto the usable length of the existing 4” cement asbestos public water main on the east side of the property. This existing public water main was constructed per Tucson Water Work Order 7095 in 1974 within a 10’ public utility easement created by the San Clemente Blocks 7 & 8 final plat recorded at BK 07, M&P, Page 019. b. The water meter shown on the tentative plat for Proposed Parcel 2 will be in Proposed Parcel 1’s real property frontage onto the existing 10’ wide public utility easement where the existing 4” public water main is located. This causes the water meter for Proposed Parcel 2 to be a “remote meter” as defined by Tucson Water’s Remote Meter Policy No. IV-B.08, Eff. 07/14/2009. c. The private water service line from the water meter for Proposed Parcel 2 will lie partially on Proposed Parcel 1. This also causes the water meter for Proposed Parcel 2 to be a “remote meter” as defined by Tucson Water’s Remote Meter Policy No. IV-B.08, Eff. 07/14/2009. d. My calculations indicate the existing 4” public water main extends just 10’ past the common lot line between the parent parcel (Lot 11) and the parcel to the north (Lot 12). This makes the existing water meter for Proposed Parcel 1 an existing remote meter as defined by Tucson Water’s Remote Meter Policy No. IV-B.08, Eff. 07/14/2009 e. Per this policy, “a remote meter will not be an authorized mechanism for obtaining water.” 2. Reconfiguring Proposed Parcels 1 and2 to be a flags lot with a minimum of minimum of 15’ of real property frontage onto a different existing public water main is not an option. The parent parcel has no real property frontage onto any existing public water main, other than the existing 4’ public water main constructed under Work Order 7095. See Tucson Water’s NW151414 valve map, which shows the existing water mains in this area. Copies of the valve map(s) and ‘as-built’ plans referenced in these comments may be obtained from Tucson Water’s Mapping & GIS Center by sending an e-mail request for them to TWMapInfo@tucsonaz.gov. 3. There may be other ways to comply with Tucson Water’s Remote Meter Policy No. IV-B.08, Eff. 07/14/2009, but the only way I currently see for this proposed lot split to comply with this policy is to extend the existing 4” public water main constructed per Work Order 7095, approximately 35’ past the proposed common lot line between Proposed Parcels 1 & 2. This would give Proposed Parcels 1 and 2 the required minimum of 15’ of real property frontage onto the usable length of an existing public water main. 4. Please meet with Tucson Water’s New Services Section section staff on the 1st Floor of the City/County Public Works Building at 201 N. Stone Avenue to discuss your situation and the concept of constructing the short extension to the existing 4” public water main constructed per Work Order 7095 via a Job Order Contract. The Job Order Contract process was specifically created for small construction projects such as this one. You may arrange an appointment with Tucson Water’s New Services Section staff by calling 520-791-5164 or by sending an email to TW_Common@tucsonaz.gov. 5. Please note that Tucson Water will not be able to approve this proposed lot split until such time that a way for it to comply with Tucson Water’s Remote Meter Policy No. IV-B.08, Eff. 07/14/2009 has been found and put into place. 6. A copy of Tucson Water’s Remote Meter Policy No. IV-B.08, Eff. 07/14/2009 may be obtained by sending an e-mail request for it to me at the e-mail address shown in my signature block. Copies of the valve map(s) and ‘as-built’ plans referenced in these comments may be obtained from Tucson Water’s Mapping & GIS Center by sending an e-mail request for them to TWMapInfo@tucsonaz.gov. Any questions, comments or concerns about these comments may be directed to: Tim Rowe, P.E., Civil Engineer Tucson Water, New Development Section 201 N. Stone Avenue, #2-220 P.O. Box 27210 Tucson, AZ 85726-7210 (520) 837-2106 tim.rowe@tucsonaz.gov |
|||
| CDRC Application Completeness Express | REVIEW COMPLETED | ||||
| Commercial Building Fast | REVIEW COMPLETED | ||||
| Residential Building Fast | REVIEW COMPLETED |