Review Status: Requires Resubmit
Review Details: LAND DIVISION/LOT SPLIT v.1
Plan Number - TD-DIV-0223-00047
Review Name: LAND DIVISION/LOT SPLIT v.1
Review Status: Requires Resubmit
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
Commercial Building | NOT REQUIRED | ||||
Record Documents Express | PENDING ASSIGNMENT | ||||
Commercial Plumbing | REQUIRES RESUBMIT | 1. Each occupiable building shall have an independent connection to the public sewer. Show how access to the public sewer will be provided for parcel A. Reference: Section 701.3, IPC 2018. 2. Show how parcel A will be provided with water. Reference: Section 107.2.1, IBC 2018. |
|||
Site Engineering | REQUIRES RESUBMIT | 1. See zoning request for a residential plot plan. Stephen Blood (520) 837-4958 Stephen.blood@tucsonaz.gov |
|||
Site Zoning | REQUIRES RESUBMIT | PDSD TRANSMITTAL FROM: PDSD Zoning Review PROJECT: 5832 S 6th Ave – R-2 TD-DIV-0223-00047 Land Split (1st Review) TRANSMITTAL DATE: March 6, 2023 SECTION 2-08.0.0: LAND SPLIT 2-08.2.0 CONTENT REQUIREMENTS 1. COMMENT: 2-08.5.E – Provide a supplemental Residential Plot Plan that meets the requirements found at: https://www.tucsonaz.gov/files/pdsd/forms/Residential_Plot_Plan_Requirements.pdf, The plot plan shall show all structures that are on this site along with perimeter yard setbacks to the proposed property line and a lot coverage calculation. Required perimeter yard setbacks are based on a measurement from design grade to the highest point of the exterior wall UDC Article 6.4.5.B & Figure 6.4.5-A. The minimum setback is the greater of six (6) feet, or two-thirds (2/3) the height of the structure’s wall facing each interior property line (Table 6.3-2.A). If any of the proposed setbacks to not meet the minimum additional comments maybe forth coming. If you have any questions about this transmittal, please contact Nicholas Martell at Nocholas.Martell@tucsonaz.gov. |
|||
TW New Development Review | REQUIRES RESUBMIT | TD-DIV-0223-00047 - Land Division_Land Split_Lot Split v1 – 5832 S 6TH AV 1. Tucson Water’s records indicate that there is an existing water meter that can serve proposed Parcel A, but no existing water meter that can serve proposed Parcel B. 2. Tucson Water’s Remote Meter Policy requires that all new lots created by lot splits have a minimum of 15’ of real property frontage onto a street, alley or existing water easement that contains a public water main. It also prohibits the private water service line for one parcel to cross another parcel. 3. To meet the requirements of Tucson Water’s Remote meter policy, a new water service line and water meter will need to be obtained to serve the existing structure on Parcel B. The new water service line will need to connect to the existing 12” water main in 6th Avenue. It may not be connected to the existing 3” water main to the south. 4. The language in Item 3 above must be added as a General Note to the Record of Survey for this lot split. 5. Any questions, comments or concerns about these comments may be directed to: Tim Rowe, P.E., Civil Engineer Tucson Water, New Development Section 201 N. Stone Avenue, #2-220 P.O. Box 27210 Tucson, AZ 85726-7210 (520) 837-2106 tim.rowe@tucsonaz.gov |
|||
CDRC Application Completeness Express | REVIEW COMPLETED | ||||
Residential Building | REVIEW COMPLETED |