Plan Number: TD-DIV-0223-00047
Parcel: 138120080

Address:
5832 S 6TH AV

Review Status: Requires Resubmit

Review Details: LAND DIVISION/LOT SPLIT v.4

Plan Number - TD-DIV-0223-00047
Review Name: LAND DIVISION/LOT SPLIT v.4
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
Record Documents Express PENDING ASSIGNMENT
Site Engineering REQUIRES RESUBMIT See zoning comments about site plan
Site Zoning REQUIRES RESUBMIT PDSD TRANSMITTAL

FROM: PDSD Zoning Review

PROJECT: 5832 S 6th Ave – R-2
TD-DIV-0223-00047
Land Split (3rd Review)

TRANSMITTAL DATE: August 11, 2023

SECTION 2-08.0.0: LAND SPLIT

2-08.2.0 CONTENT REQUIREMENTS
1. This comment was not addressed. No additional information has been added to the plan. COMMENT: 2-08.5.E – Provide a supplemental Residential Plot Plan that meets the requirements found at: https://www.tucsonaz.gov/files/pdsd/forms/Residential_Plot_Plan_Requirements.pdf, The plot plan shall show all structures that are on this site along with perimeter yard setbacks to the proposed property line and a lot coverage calculation. Required perimeter yard setbacks are based on a measurement from design grade to the highest point of the exterior wall UDC Article 6.4.5.B & Figure 6.4.5-A. The minimum setback is the greater of six (6) feet, or two-thirds (2/3) the height of the structure’s wall facing each interior property line (Table 6.3-2.A). If any of the proposed setbacks Do not meet the minimum additional comments maybe forth coming.

If you have any questions about this transmittal, please contact Nicholas Martell at Nocholas.Martell@tucsonaz.gov.
TW New Development Review REQUIRES RESUBMIT TD-DIV-0223-00047 - Land Division_Land Split_Lot Split v1 – 5832 S 6TH AV

1. To ensure the requirements of Tucson Water Remote meter policy, add a WATER NOTE to the the Record of Survey that reads:

TO MEET THE REQUIREMENTS OF TUCSON WATER’S REMOTE METER POLICY, A NEW WATER SERVICE LINE AND WATER METER WILL NEED TO BE OBTAINED TO SERVE THE EXISTING STRUCTURE ON PARCEL B. THIS NEW WATER SERVICE LINE WILL NEED TO CONNECT TO THE EXISTING 12” WATER MAIN IN 6TH AVENUE. IT MAY NOT BE CONNECTED TO THE EXISTING 3” WATER MAIN TO THE SOUTH.

2. Show the approximate location of the new water service lines and water meter for Parcel B on the Residential Plot Plan, that the Site Zoning Reviewer has required.

3. Any questions, comments or concerns about these comments may be directed to:

Tim Rowe, P.E., Civil Engineer
Tucson Water, New Development Section
201 N. Stone Avenue, #2-220
P.O. Box 27210
Tucson, AZ 85726-7210
(520) 837-2106
tim.rowe@tucsonaz.gov
CDRC Application Completeness Express REVIEW COMPLETED