Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Plan Number: TD-DIV-0223-00037
Parcel: 12607113A

Address:
4025 E BURNS ST

Review Status: Requires Resubmit

Review Details: LAND DIVISION/LOT SPLIT v.1

Plan Number - TD-DIV-0223-00037
Review Name: LAND DIVISION/LOT SPLIT v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
Site Engineering APPROVED
Record Documents Express PENDING ASSIGNMENT
Site Zoning REQUIRES RESUBMIT CDRC TRANSMITTAL

TO: Development Services Department

Plans Coordination Office

FROM: Paul Camarena

PDSD Zoning Review Section

PROJECT: 4025 E BURNS ST

Land Split (1st Review)

TD-DIV-0223-00037
TRANSMITTAL DATE: 2/7/2023


COMMENTS: Please resubmit revised drawings along a detailed response letter, which states how all Zoning Review Section comments were addressed.

This plan has been reviewed for compliance with the Unified Development Code (UDC) 8.3.1 Land Split and Administrative Manual (AM) Section 2-08. Also compliance with applicable development criteria for the proposed or existing use as listed in the City of Tucson Uniform Development Code (UDC) and the UDC Technical Standards Manual (TSM).

8.3.1. LAND SPLIT

A. Purpose
A.M. 2-08.1.0 PURPOSE

The purpose of this Section is to provide the submittal requirements for land splits.

2-08.2.0 APPLICABILITY

Proposed land splits as defined in Article 8 of the Unified Development Code (UDC) shall be prepared according the requirements provided below.

2-08.5.0 CONTENT REQUIREMENTS

The drawing showing the proposed land split shall include the following:


D. All proposed easements on and surrounding the property;


F. The setbacks of existing buildings and structures from existing and proposed property lines;
COMMENT: Provide a setback dimension for the chimney located on the south west portion of the property. The setback would be based on a wall height of 11ft the required setback 7’4”.

G. The land area of each proposed lot in square feet or acreage. If the property is developed, additional information, such as but not limited to FAR, lot coverage, vehicle and bicycle parking, may be needed;
COMMENT: Revise the lot coverage calculation, the lot coverage is for each proposed lot.

If you have any questions about this transmittal, Contact Paul Camarena at (520) 837-4986 or by email Paul.Camarena@tucsonaz.gov

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised final plat.
CDRC Application Completeness Express REVIEW COMPLETED
Residential Building REVIEW COMPLETED
TW New Development Review REVIEW COMPLETED 1. Tucson Water has no objections to the proposed Lot Split and offers the following comment for your convenience.
2. The Record of Survey shows the existing cleanout for the existing home on Parcel A, located on the property line/ right of way line for Parcel B. Therefore, it is reasonable to assume that the house connection sewer from the existing home on Parcel A crosses the southwest corner of Parcel B. Please contact the Pima County Regional Wastewater Management Department and verify this is acceptable to the PCRWRD. It may not.
3. Please note that my review of this lot split did not include reviewing the legal descriptions of the proposed lots, as I assume others will be reviewing those.
4. Any questions, comments or concerns about these comments may be directed to:

Tim Rowe, P.E., Civil Engineer
Tucson Water, New Development Section
201 N. Stone Avenue, #2-220
P.O. Box 27210
Tucson, AZ 85726-7210
(520) 837-2106
tim.rowe@tucsonaz.gov