Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Plan Number: TD-DIV-0124-00006
Parcel: 12213074B

Review Status: Requires Resubmit

Review Details: LAND DIVISION/SUBDIVISION v.1

Plan Number - TD-DIV-0124-00006
Review Name: LAND DIVISION/SUBDIVISION v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
Commercial Building APPROVED
Commercial Plumbing APPROVED
NPPO APPROVED
Residential Building APPROVED
CDRC Post Review Express PENDING ASSIGNMENT
External Reviewers - Pima County Assessor REQUIRES RESUBMIT Office of the Pima County Assessor
240 N. Stone Ave.
Tucson, Arizona 85701
SUZANNE DROUBIE
PIMA COUNTY ASSESSOR
TO: City of Tucson Development Services
FROM: Michael Bell
GIS Cartographer
Pima County Assessor’s Office
Michael.Bell@pima.gov
(520)724-7503
DATE: February 29, 2024
RE: Assessor’s Review and Comments Regarding: (SUBMITTAL 1)
TD-DIV-0124-00006 – Lots 4&5 Block 5 SPEEDWAY ADDITION #1
– Record of Survey
* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * *
Plat meets Assessor’s Office requirements.
__X___ Plat does not meet Assessor’s Office requirements.
COMMENTS:
The assessor’s office does not review anything except final plats.
When TD-DIV-0124-00006 is submitted for review as final plat, please
include the assessor’s office in the review.
See below for the generalized requirements the Assessor’s Office reviews for:
 The title block must be in the lower right-hand corner and it must have
the number of lots or units or block or elements or any combination of
these. It must have the common areas listed if there are any. It must
have the section, township, and range and if it is a resubdivision, it
must mention the plat name and the map & plat.
 The location map must be in the upper right-hand corner and must have
the section, township, and range. The project area should be outlined
and/or have an arrow pointing to it.
 General notes must have the gross area of the subdivision, the number of
lots, the number of miles of new road, public or private (even if the
number is 0), and the Basis of Bearings.
 There must be a section tie, with a bearing and dimension from the
section corner or quarter corner to the point of tie on the subdivision.
 The perimeter line must be solid and the heaviest lineweight on the
plat. The lot lines and common area lines must be solid and the next
heaviest. Lines for erosion setbacks, floodplain lines etc. should be
the lightest lineweight and be dashed or dot-dashed.
 There must be bearings and dimensions for the perimeter and all lot
lines and all common areas.
 All lots must be numbered and have square footage. If the area is too
small, there can be a table to the side for the square footage.
 All hatching, stippling, striping, etc. must be removed in the final
plat, unless another agency requires it. If so, all lettering must have
the hatching, etc. cut away so they are legible.
 All streets must be named in the final plat, and have dimensions,
bearings, and curve data.
 All adjacent subdivisions should be named, with map and plat in the
appropriate areas around the subdivision.
 Ownership printed in the Dedication section must match Assessor data.
For APN 122-13-074B ownership is currently held by: CONTRERAS LAURA.
NOTE: THE ASSESSOR’S CURRENT INVOLVEMENT IN PROCESSING ITS MANUAL MAPS TO DIGITAL FORMAT IS EXPEDITED GREATLY BY EXCHANGE OF DIGITAL DATA. IN THE COURSE OF RECORDING THIS SUBDIVISION YOUR ASSISTANCE IN PROVIDING THIS OFFICE WITH AN AUTOCAD COPY WOULD BE GREATLY APPRECIATED. AUTOCAD DWGS CAN BE SENT TO THE EMAIL ABOVE. THANK YOU FOR ANY DIGITAL DATA PREVIOUSLY SUBMITTED.
External Reviewers - Pima County Wastewater (RWRD) REQUIRES RESUBMIT The applicant is responsible for obtaining review and approval by Pima County, for projects involving RWRD sewers, on-site wastewater treatment facilities and public water systems https://www.pima.gov/1766/Wastewater-Reclamation. The applicant must provide an Approval letter from RWRD, prior to PDSD Approving the permit.
Site Engineering REQUIRES RESUBMIT 1. It is difficult to discern whether this is intended to be a lot split or a minor subdivision. Provide a figure that shows how the lots were oriented before the land division was completed.


Lianne Evans
lianne.evans@tucsonaz.gov
Site Zoning REQUIRES RESUBMIT CDRC TRANSMITTAL
FROM: PDSD Zoning Review

PROJECT: TD-DIV-0124-00006
3902 E FAIRMOUNT ST
FINAL PLAT, MINOR SUBDIVISION (1st Review)

TRANSMITTAL DATE: March 7, 2024
DUE DATE: March 3, 2024

COMMENTS: Resubmit revised drawings along with a detailed response letter, which states how all Zoning Review Section comments were addressed.
2-07.1.0 APPLICABILITY
Final plats, block plats, minor subdivisions, and condominium plats shall be prepared according to the requirements provided below. Hereafter referred to as “plat” or “plats.”
A final plat serves as a survey document suitable for recordation of all or part of an approved tentative plat, if applicable. The final plat must conform to the approved tentative plat or site plan in lot configuration, design, and required conditions of development. The final plat, once approved, is recorded in the Pima County Recorder’s Office. The final plat is kept on file and becomes part of the permanent record for the subject site.

1. COMMENT: The proposed land division is not eligible for a simple land split and must meet the requirements of AM 2-07 Final Plat (Minor Subdivision) to accomplish the proposed land division - https://codelibrary.amlegal.com/codes/tucson/latest/tucson_az_udc/0-0-0-8971

Per UDC 11.4.13, a land split is the division of improved or unimproved land for the purpose of sale or lease, which is not defined as a subdivision, whose area is two and one-half or less in size, into tracts or parcels if previously platted, or three tracts or parcels of land or less if not previously platted. As the proposal is to divide the originally platted parcel into four lots, it does not meet the definition of the land split. For more information refer to UDC 8.4.3 Minor Subdivision.

If you have any questions about this transmittal, please contact Loran Shamis at Loran.Shamis@tucsonaz.gov.
RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised Final Plat (Minor Subdivision) and comment response letter. To resubmit visit Tucson Development Center at https://tdc-online.tucsonaz.gov/#/home.
Instructions for resubmittal - https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/tdc-faq/new-pdfs/revisions-and-resubmittals.pdf
CDRC Application Completeness Express REVIEW COMPLETED
CDRC Review Coordinator Express REVIEW COMPLETED Per SOP Addressing review not required. RWRD review required per SOP. Review request email sent per Assessors & TEP. CDRC sent FYI email to PAG, USPS, SWG.
External Reviewers - Pima Association of Governments REVIEW COMPLETED CDRC sent FYI email to PAG, USPS, SWG. No further action is required from the customer at this time.
External Reviewers - Southwest Gas REVIEW COMPLETED CDRC sent FYI email to PAG, USPS, SWG. No further action is required from the customer at this time.
External Reviewers - Tucson Electric Power (TEP) REVIEW COMPLETED Greetings,
Tucson Electric Power Co. (TEP) has reviewed and has no objection to plans submitted on March 12th, 2024. There are existing TEP facilities within the boundaries of the plat. Costs for removing or relocating existing TEP facilities will be billable to the developer.
Please call the New Construction Department at 520-918-8300 to apply for service for new development. Submit a final set of approved plans, including electrical load and offsite improvement plans, to determine how TEP will serve this development. If easements are required for new TEP facilities, they will be obtained by separate instrument.
Respectfully,
Tucson Electric Power Co.
Land Resources Department
External Reviewers - United States Postal Service (USPS) REVIEW COMPLETED CDRC sent FYI email to PAG, USPS, SWG. No further action is required from the customer at this time.
Fire New Construction REVIEW COMPLETED
New Services/JOC REVIEW COMPLETED TD-DIV-0124-00006 - Land Division_Subdivison v1 – 3902 E FAIRMOUNT ST

1. Tucson Water has no objections to the proposed lot layout shown on the .pdf file named 2022-275 Lots 4 & 5 Blk 5 Speedway Addition No 1 Lot Split - Beau Borboa LotSplit_v1.pdf.

2. If the lot layout changes on any future submittal, this approval is null and void, and Tucson Water will need to review the new lot layout.

3. Any questions, comments or concerns about these comments may be directed to:

Tim Rowe, P.E., Civil Engineer
Tucson Water, New Development Section
201 N. Stone Avenue, #2-220
P.O. Box 27210
Tucson, AZ 85726-7210
(520) 837-2106
tim.rowe@tucsonaz.gov
OK to Submit - Engineering Fast REVIEW COMPLETED
OK to Submit - Zoning Fast REVIEW COMPLETED