Plan Review Detail
Review Status: Requires Resubmit
Review Details: LAND DIVISION/LOT SPLIT v.1
Plan Number - TD-DIV-0124-00003
Review Name: LAND DIVISION/LOT SPLIT v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| Commercial Plumbing | APPROVED | ||||
| Residential Building | APPROVED | ||||
| TW New Development Review | APPROVED | TD-DIV-0124-00003 - Land Division_Land Split_Lot Split v1 – 5804 E FAIRMOUNT ST 1. Tucson Water has no objections to the proposed Land Split / Lot Split. 2. Any questions, comments or concerns about these comments may be directed to: Tim Rowe, P.E., Civil Engineer Tucson Water, New Development Section 201 N. Stone Avenue, #2-220 P.O. Box 27210 Tucson, AZ 85726-7210 (520) 837-2106 tim.rowe@tucsonaz.gov |
|||
| Commercial Building | NOT REQUIRED | Not commercial, see Residential Building comment. | |||
| Record Documents Express | PENDING ASSIGNMENT | ||||
| Site Engineering | REQUIRES RESUBMIT | 1. The original parcel (lot 6, bkl 8 of mountain acre farms) has already been split into three parcels, anymore divisions will require a new subdivision be platted. This can not be a done as a lot split. Stephen Blood (520) 837-4958 Stephen.blood@tucsonaz.gov |
|||
| Site Zoning | REQUIRES RESUBMIT | PDSD TRANSMITTAL FROM: PDSD Zoning Review PROJECT: 5804 E FAIRMOUNT ST. – R-1 TD-DIV-0124-00003 Land Split (1st Review) TRANSMITTAL DATE: January 17, 2024 SECTION 2-08.0.0: LAND SPLIT 2-08.5.0 CONTENT REQUIREMENTS The drawing showing the proposed land split shall include the following: 1. 2-08.5.F - COMMENT: Perimeter yard setbacks are based on a wall height measurement from design grade to the highest point of the exterior wall UDC Article 6.4.5.B & Figure 6.4.5-A. In this case it will be the measurement from design grade to the top of parapet. Provide the east wall height so that the required perimeter yard setback can be determined. R-1 Zone the required perimeter yard setback from the east wall of the duplex to the east property line is 6’-0” or 2/3 (H) height of the exterior wall. The proposed 5’-0” will require a Design Development Option ( will be required. DDO application and requirements can be found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Planning-Zoning-Applications/Zoning-Administration. If you have questions about the DDO application or process please contact Wyatt Berger at Wyatt.Berger@tucsonaz.gov or Georgia Pennington at Georgia.Pennington@tucsonaz.gov. 2. 2-08.5.F - COMMENT: Provide a lot coverage calculation for parcel 1 that meets the requirements of UDC Article 6.4.3 and the example shown on the Residential Plot Plan Requirements found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Building-Safety/Plan-Examples/Plot-Plan-Example. 3. 2-08.5.F - COMMENT: Per UDC Table 4.8-2 & Table 6.3-2.A the minimum lot size for an R-1 lot with two (2) dwelling units is 10,000 sq. ft. A rezoning maybe required or possibly a Board of Adjustment for Variance will be required. Board of Adjustment application/requirements can be found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Planning-Zoning-Applications/Zoning-Administration. Contact for the Board of Adjustment is Mark Castro at Mark.Castro@tucsonaz.gov. If you have any questions about this transmittal, please contact Nicholas Ross at Nicholas.Ross@tucsonaz.gov. |
|||
| CDRC Application Completeness Express | REVIEW COMPLETED |