Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: TD-DEV-1225-00316
Parcel: 118061140

Address:
1901 W KING AV

Review Status: Requires Resubmit

Review Details: DEVELOPMENT PACKAGE NEW v.1

Permit Number - TD-DEV-1225-00316
Review Name: DEVELOPMENT PACKAGE NEW v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
01/21/2026 Commercial Plumbing Standard REQUIRES RESUBMIT ACTIVITY NO. TC-COM-1225-02329
ADDRESS/PARCEL: (1901 W KING AV TUCSON, AZ 85713)

Submit your revised drawings along with a detailed response letter, which states how all comments were addressed. Review will not proceed without the response letter. The submitted documents were incomplete and a thorough plan review could not be performed. Please be aware, new comments may arise with the next review.

If you have any questions about these review comments, I can be reached at Sean.Severson@tucsonaz.gov

COMMENTS:

1. Show the location of all cleanouts for the building sewer. Building sewers shall have cleanouts located at intervals of not more than 100 feet. Reference: Section 703.5 and 708.1.2, IPC 2018.
01/30/2026 NPPO Standard REQUIRES RESUBMIT See site landscape comments for NPPO Waiver requirement.

Thank you.
Chad Keller, RLA
chad.keller@tucsonaz.gov
01/07/2026 Site Engineering Standard REQUIRES RESUBMIT Permit: TD-DEV-1225-00316
Location: 1901 W KING AV
Review Date: 1/7/2026

This plan has been reviewed for compliance with applicable development criteria in the City of Tucson Unified Development Code (UDC) Administrative Manual (AM) Section 2-6 and Technical Manual (TM) Section for waste management, Pedestrian Access, Hydrology -Retention/Detention Requirements, and all site standard code.
Drainage Manual Link: https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/engineering-code/cot-drainage-manual-searchable.pdf
Design standards for Stormwater Detention and Retention Link:
https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/engineering-code/updated-retention-detention-manual.pdf

Site Engineering Administrative/content Comments:
1. Provide the development package case number, TD-DEV-1225-00316, adjacent to the title block on all sheets.
2. Will there be a perimeter fence/wall proposed for the development?
3. The title block shows the APN: 18-06-1140, but the actual parcel ID is 118-06-1140, revise accordingly.
4. As previously called-out in prior a Pre-application meeting, a lot combination will be required with 1881 W King St, as it appears to be operating as a single site. This will require that parcel 118-06-116F be included in all site documentation, reports, and site calculations. Refer to Site Zoning for further comments regarding this.
5. Include general note - “Any wastewater discharged into the public sanitary sewerage system shall meet the requirements of Pima County Ordinance No. 1991-140, as currently amended.” AM 2-06.4.7.E.3
6. Provide site expansion calculations on the cover sheet. AM 2-06.4.7.A.8.c
Waste Collection Comments:
7. It should be noted that - Use of APCs for multi-family, commercial, or industrial development requires prior approval from Environmental Services. TSM 8-01.4.G The person of contact shall be Andy Vera at Andy.Vera@tucsonaz.gov
a. Until Approval is provided, it will be required that a trash enclosure detail in compliance with TSM 8-01.5.0 be provided for construction.
Pedestrian Circulation Comments:
8. A sidewalk is required adjacent and parallel to any access lane or PAAL on the side where buildings are located. TSM 7-01.4.0. Please demonstrate how this is achieved for the existing Church office on the north side of the property.
9. Clearly show downspouts and sidewalk scuppers. to ensure that stormwater from roof drains, up to and including flow from the ten-year storm event, does not pass over sidewalks per Technical Standards Manual 7-01.4.3E. This should be done for both existing and new buildings on the entire site as the expansion of this site is proposed to exceed 25%, triggering full compliance with standards set forth.
10. Please label the turning radius for the fire truck turnaround shown. Outer radius minimum = 50’
11. Pedestrian circulation is required to connect all buildings, dumpster areas, common areas, and the sidewalk on all the street frontages per TSM 7-01.3.3. Demonstrate how this is achieved to the bicycle parking and APC storage area.
Drainage comments:
12. The drainage report will need to be revised – the property is located within the West Branch Santa Cruz River watershed which carries a Critical basin designation. As required by critical basin detention requirements – it will be required that the development provide reduction of peak site discharge to 85% of the pre-developed levels. DSSDR 3.1 This is due to the critical designation as well as problems experienced in the surrounding area relating to drainage
a. It would be possible to consider reducing/eliminating full retention requirements in-lieu of sufficient detention being provided – justification: Majority D soils as well as new a mapped wash
13. It is required that rainwater harvesting basins carry a Minimum 10 feet setback from structures DSSDR 5.3.1.11.d Demonstrate how this will be addressed for WH area 4
14. Due to the proximity to the San Juan Wash, provide an erosion hazard section to the drainage report to show if there is any erosion hazard setback. If it is determined that the wash carries an EHS, it will need to delineated and called-out on the grading plan.
15. Add the 100-year water surface elevation (WSE) to all basin descriptor boxes on sheet 4

It should be noted that additional Site Engineering comments may be forthcoming in future review cycles as provided comments and development changes may bring forth further callouts.

If you have any questions or concerns, please contact
Marco Contreras
Marco.contreras@tucsonaz.gov
01/30/2026 Site Landscape Standard REQUIRES RESUBMIT PLANNING AND DEVELOPMENT SERVICES DEPARTMENT
REVIEWER: CHAD KELLER, RLA
SITE LANDSCAPE/NATIVE PLANT PRESERVATION SECTION

PROJECT: WESTSIDE CHURCH OF GOD
ACTIVITY NO: TD-DEV-1225-00316
ADDRESS: 1901 W KING AV
ZONING: R-1 RESIDENCE ZONE
LAND USE: RELIGIOUS/REVIEWED AS ALL OTHER USES PER UDC TABLE 7.6.4-1 FOR LANDSCAPE BORDERS
01.30.2026

THE PROPOSED PLANS HAVE BEEN REVIEWED FOR COMPLIANCE WITH APPLICABLE DEVELOPMENT STANDARDS PER THE CITY OF TUCSON UNIFIED DEVELOPMENT CODE (UDC), TECHNICAL STANDARDS MANUAL (TSM), AND ADMINISTRATIVE MANUAL (AM) FOR SITE LANDSCAPE, NATIVE PLANTS, AND RAINWATER HARVESTING.

RESUBMIT REVISED DRAWINGS ALONG WITH A DETAILED RESPONSE LETTER, STATING HOW ALL SITE LANDSCAPE AND NPPO SECTION REVIEW COMMENTS HAVE BEEN ADDRESSED.

SITE LANDSCAPE/NPPO SECTION COMMENTS:

1. Any planting or irrigation proposed in the ROW needs approval from DTM landscape architect, David Marhefka – david.marhefka@tucsonaz.gov. Coordinate with David and he will provide a written memorandum of approval if there are no conflicts. Or move all required landscape items on to the property side of the ROW line.

2. Include the calculation for vegetative ground cover (shrubs, groundcover/vines) at the required 50 percent within the street landscape border.

3. King Av is designated as a minor local road. This street landscape border needs to include a 5’ vegetative screen at the project side of the border.

4. ALL OTHER USES per UDC Table 7.6.4-1 requires a 5’ screen on the east Residence zone property line. This can be a vegetative screen or a fence, or a wall. Similar to what is shown on the west property line with the wood fence. See UDC 7.6.5.B SCREENING MATERIALS. Clearly indicate the screen and call it out on the landscape and civil plans.

5. Include proposed plant quantities in the planting schedule.

6. The Blue Palo Verde at the southeast corner of the building is located in a pretty narrow space. Look at moving it to the south to avoid maintenance issues due to conflict with the building and the tree.

7. Include schematic locations for irrigation lines and sleeves across hardscape. Also include connection equipment on the irrigation plan. Include an irrigation details sheet.

8. An irrigation only meter is required, see TSM 4-01.6.0. Include the “irrigation only” meter on the irrigation plan. Also see City of Tucson Ordinance 10597 -- Sec. 6-182. Rainwater Harvesting Plan: Number 3 (a) A separate water meter connected to the main water supply; or (b) An irrigation sub-meter.

9. Include a sheet for planting details. Include a tree planting near hardscape detail that includes root barriers. The root barrier detail example can be found here: https://www.tucsonaz.gov/Departments/Transportation-Mobility/Landscape/Landscape-Architects

10. Provide a calculation for required and provided canopy trees in the parking area. The plan is in compliance, we just want to see the calculations for our records and ease of review.

11. Remove references to Decomposed Granite and call out a sized screened rock and designers color choice. IE: ¾” screened rock, Coronado brown or approved equal.

12. On the commercial rainwater harvesting plan, add flow line direction symbology and spot elevations. Spot elevations at the curb cut inlet, bottom of basin and curb cut outlets. The elevations add clarity in review and for site inspections.

13. Provide a Native Plant Preservation Plan or a NPPO Waiver with the next submittal. If a copy of the waiver is needed, contact the email below and I will send a copy. The following link includes a fillable PDF of the waiver for your use as well.

https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/applicationsforms/nppoapp-2025-v.2-fillable-1.pdf

14. Provide the development package case number, TD-DEV-1225-00316, adjacent to the title block on all site landscape sheets, per Administrative Manual 2-06.4.3

15. Prior to Site Landscape Development Package approval, ensure that Site Zoning and Site Engineering comments are completely addressed.

Thank you.
Chad Keller, RLA
Landscape Architect
chad.keller@tucsonaz.gov
520.837.4923
01/28/2026 Site Zoning Standard REQUIRES RESUBMIT CDRC TRANSMITTAL

FROM:
Bobby Parsons
PDSD Zoning Review Section

PROJECT:
Westside Church of God Expansion – 1901 W. King Ave. Tucson, AZ 85713
Development Package (1st Review)
TD-DEV-1225-00316

TRANSMITTAL DATE: 1/28/2026
DUE DATE: 1/27/2026

COMMENTS: Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed.

Section 3.3.3.G.5.c UDC, An applicant has one year from the date of application to obtain approval of a site plan that complies with zoning and other development requirements in effect at the time of application, unless an ordinance adopted by Mayor and Council during this period states otherwise. A site plan application that has been in review for a period of one year and has not yet been approved is considered denied. To continue the review of a site plan for the property, a new site plan must be submitted that complies with regulations in effect at the time of re-submittal. The new submittal initiates a new one-year review period. One year Expiration date is January 5, 2027.

SECTION 2-06.0.0: DEVELOPMENT PACKAGE (TENTATIVE PLATS AND SITE PLANS)

2-06.3.0 FORMAT REQUIREMENTS

CONTENT REQUIREMENTS

2-06.4.1 - The name, mailing and email addresses, and phone number of the primary property owner of the site, the developer of the project, registrant(s), and other person(s), firm(s), or organization(s) that prepared the development package documents shall be provided on the right half of the cover sheet. The applicable registration or license number shall be provided if prepared by or with the assistance of a registered professional, such as a surveyor, architect, landscape architect, or engineer. All sealing shall be consistent with Arizona Board of Technical Registration guidelines.

1. COMMENT: 2-06.4.1 – Please include the information as noted by the standard above. 3 pages were stamped by Jeff Stanley however his contact information was not included on Sheet 1.

2-06.4.2 - The title block shall include the following information and be provided on each sheet:

2-06.4.3 - The administrative street address and relevant case numbers (development package document, subdivision, rezoning, board of adjustment, DDO, MDR, DSMR, overlay, etc.) shall be provided adjacent to the title block on each sheet.

2. COMMENT: 2-06.4.3 - Provide the development package case number, TD-DEV-1225-00316, adjacent to the title block on each sheet.

2-06.4.4.C - Section, township, and range; section corners; north arrow; and the scale will be labeled.

3. COMMENT: 2-06.4.4.C – The eastern section corners listed are incorrectly labeled as noted by the standard above.

2-06.4.7 - General Notes
The following general notes are required. Additional notes specific to each plan are required where applicable.

Zoning and Land Use Notes

2-06.4.7.A.4 - Identify the existing and proposed use of the property as classified per the UDC. List all UDC sections applicable to the proposed uses.

4. COMMENT: 2-06.4.7.A.4 – The proposed use is listed as religious however in the vehicular parking requirements, you refer to sanctuary use. Please clarify the discrepancy.

2-06.4.7.A.6 - If a plan or plat is prepared in conjunction with other applications or overlays or the parcel being developed is subject to conditions of an application processed previously, additional information must be added to the plan. Such applications and overlays include, but are not limited to: annexations; rezonings; special exceptions; Board of Adjustment variances; Design Development Options; Technical Standard Modification Request; overlays (Airport Environs Zone, Environmental Resource Zone, Gateway Corridor Zone, Hillside Development Zone, Historic Preservation Zone, Major Streets and Routes, Rio Nuevo District, Scenic Corridor Zone, WASH); Modification of Development Regulations through the Downtown Area Infill Incentive District or Rio Nuevo District; Downtown Heritage Incentive Zone; or, Design Review Board. Provide the following information on the plan.

5. COMMENT: 2-06.4.7.A.6 – Include a note stating “this project is designed to meet the overlay zone(s) criteria. UDC Article 5.7 Environmental Resource Zone (ERZ).

2-06.4.7.A.8 - For development package documents provide:

2-06.4.7.A.8.a - Floor area for each building;

6. COMMENT: 2-06.4.7.A.8.a – Under total existing buildings you state 3,026 sf however in the parking calculations, you state existing buildings are 4,530 sf. Please clarify the discrepancy. Also, please see comment 8 as it relates to buildings and square footage of the adjacent parcel which need to be included in the calculations.

2-06.4.7.A.8.c - Percentage of building, lot area, or vehicular use area expansion. If the building(s) or lot area have been previously expanded, those calculations shall be included; and,

7. COMMENT: 2-06.4.7.A.8.c – Please include the expansion calculations as noted by the standard above.

2-06.4.8 - Existing Site Conditions
The following information shall be provided on the plan/plat drawing to indicate the existing conditions on site and within 50 feet of the site. On sites bounded by a street with a width of 50 feet or greater, the existing conditions across the street will be provided.

2-06.4.9 - Information on Proposed Development
The following information on the proposed project shall be shown on the drawing or added as notes.

2-06.4.9.A - Draw in all proposed lot lines with approximate distances and measurements.

8. COMMENT: 2-06.4.9.A - As this site is made up of two (2) parcels, 118061140 and 11806116F, a lot combination is required. Either provide the approved lot combination request form or a recorded Covenant Regarding Development and Use of Real Property with your next submittal. Contact Pima County for the Combo Request. The Covenant can be found at: https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/submission-documents/covenant-regarding-development-and-use-of-real-property-udc-with-release.pdf. Also, please update your site calculations to account for the additional building square footage, lot coverage, and gross area of the site as both parcels will be reviewed as one site.

2-06.4.9.H.5.a - Show all motor vehicle off-street parking spaces provided, fully dimensioned. As a note, provide calculations on the number of spaces required (include the ratio used) and the number provided, including the number of spaces required and provided for the physically disabled. The drawing should indicate parking space locations for the physically disabled. A typical parking space detail shall be provided for both standard parking spaces and those for the physically disabled. For information on parking requirements for the physically disabled, refer to adopted building and accessibility codes of the City of Tucson. Design criteria for parking spaces and access are located in Section 7.4.6, Motor Vehicle Use Area Design Criteria, of the UDC.

9. COMMENT: 2-06.4.9.H.5.a – The parking calculations do not include the existing or proposed office space. Please update the calculations to include these items that were not included. If you cannot meet the minimum required parking requirements, an Individual Parking Plan (IPP) can be applied for to reduce the required number of parking spaces. Please reach out to Mark Castro at Mark.Castro@tucsonaz.gov if you have questions about the IPP process.
Also, please include a note stating one of the accessible parking spaces will be van accessible.

2-06.4.9.Q - Provide the square footage and the height of each commercial, industrial, or business structure and the specific use proposed within the footprint of the building(s).

10. COMMENT: 2-06.4.9.Q – Please provide the height of the proposed new buildings within the footprint as noted by the standard above.

2-06.4.9.R - Show on-site pedestrian circulation and refuge utilizing location and the design criteria in Section 7-01.0.0, Pedestrian Access, of the Technical Standards Manual.

11. COMMENT: 2-06.4.9.R – Please demonstrate on-site pedestrian circulation including to refuse collection areas as noted by the standard above.

***For additional information on the any standard presented in this memo, please refer to the City of Tucson “Unified Development Code” – Administrative Manual Section 2-06 or Technical Standards noted in the comments. https://www.tucsonaz.gov/pdsd/all-codes-plans-determinations


If you have any questions about this transmittal, Contact Bobby Parsons at Robert.Parsons@tucsonaz.gov.

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development package and comment response letter. To resubmit visit Tucson Development Center at https://tdc-online.tucsonaz.gov/#/home.
Instructions for resubmittal - https://www.tucsonaz.gov/files/pdsd/website/Resubmittals.pdf.
01/06/2026 CDRC Review Coordinator Express REVIEW COMPLETED EXTERNAL REVIEWERS
CDRC added: TEP, SWG, USPS, and PAG to the workflow. Review request email sent to TEP , and FYI email sent to, SWG USPS PAG.
01/06/2026 External Reviewers - Pima Association of Governments Standard REVIEW COMPLETED CDRC sent FYI email sent to PAG, USPS, SWG. No further action is required.
01/06/2026 External Reviewers - Southwest Gas Standard REVIEW COMPLETED CDRC sent FYI email sent to PAG, USPS, SWG. No further action is required.
01/20/2026 External Reviewers - Tucson Electric Power (TEP) Standard REVIEW COMPLETED 4350 E. Irvington Road
Post Office Box 711, Tucson, AZ 85702
January 19, 2026
WO#T173066
City of Tucson
Planning and Development Services
Attn: CDRC Admin Team
Dear CDRC Admin Team
Subject: WESTSIDE CHURCH OF GOD
TD-DEV-1225-00316
Tucson Electric Power Company (TEP) has reviewed and approved the development
plan submitted 1/6/2025. There are existing facilities within the development which are
depicted upon the plan. POSSIBLE CONFLICTS WITH OVERHEAD POLE LINE
ALONG KING AVE, PLEASE CONTACT TEP DESIGN IF RELOCATION IS
REQUIRED
Enclosed is a copy of a TEP facilities map showing the approximate location of the
existing facilities. Any relocation costs will be billable to the customer.
To apply for electric service, please call the New Construction department at (520) 918-
8300. Please submit a final set of plans including approved site, electric load, paving
off-site improvements and irrigation plans. If available, include a PDF version of the
plans.
If easements are required, they will be secured by separate instrument. Should you
have any easement questions, please contact our Land Resources Department,
LandReviews@tep.com.
Should you have any technical questions, please contact the area designer,
Martin Salazar
(520) 305-6713
msalazar@tep.com
Sincerely,
Design Admins
Design Admins
Tucson Electric Power
01/06/2026 External Reviewers - United States Postal Service (USPS) Standard REVIEW COMPLETED CDRC sent FYI email sent to PAG, USPS, SWG. No further action is required.
01/27/2026 Fire New Construction Standard REVIEW COMPLETED
01/02/2026 OK to Submit - Engineering Fast REVIEW COMPLETED
01/05/2026 OK to Submit - Zoning Fast REVIEW COMPLETED
01/27/2026 ROW Engineering Review Standard REVIEW COMPLETED Site plan:
1. Driveway (PAG SD 206) Max. width for residential driveway is 20’
2.Sidewalk (PAG SD 200) 5’ for arterial roadways.
3.Road Type: Local
4.All Work within City Of Tucson Right of Way requires Separate and Individual ROW permits per Scope of work.
*Unused existing curb cuts shall be closed.
01/12/2026 ROW Review REVIEW COMPLETED