Permit Review Detail
Review Status: Requires Resubmit
Review Details: DEVELOPMENT PACKAGE NEW REVISION v.1
Permit Number - TD-DEV-1225-00310
Review Name: DEVELOPMENT PACKAGE NEW REVISION v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 09/09/2026 | CDRC Post Review Express | PENDING ASSIGNMENT | |||
| 09/09/2026 | CDRC Review Coordinator Express | PENDING ASSIGNMENT | |||
| 09/09/2026 | Commercial Plumbing Standard | PENDING ASSIGNMENT | |||
| 09/09/2026 | Fire New Construction Standard | PENDING ASSIGNMENT | |||
| 09/09/2026 | NPPO Standard | PENDING ASSIGNMENT | |||
| 09/09/2026 | ROW Engineering Review Standard | PENDING ASSIGNMENT | |||
| 09/09/2026 | Site Engineering Standard | PENDING ASSIGNMENT | |||
| 09/09/2026 | Site Landscape Standard | PENDING ASSIGNMENT | |||
| 09/09/2026 | Site Zoning Standard | PENDING ASSIGNMENT | |||
| 09/08/2026 | OK to Submit - Engineering Fast | REQUIRES RESUBMIT | Permit Activity Number: TD-DEV-1225-00310 (OK to Submit – REV. 1) Project: Proposed construction of a shell & site work Location: 140410020, 140410040, 140410030, 140410070, 140410060, 140410050, 140410080 - 3430 E VALENCIA RD Review Date: 9/8/2026 Reviewer: Dylan Molina – Engineering Associate - Site Engineering Reviewer Contact: Dylan.Molina@tucsonaz.gov Plan review for the above referenced activity number has been completed. This letter reflects comments to address to ensure approval from Site Engineering. To facilitate timely reviews, please include a response letter, updated plans and any additional supporting calculations. In your response letter, address each comment individually and explain what changes were made and where they can be found in the plans. DO NOT mark or highlight changes in the drawings at this stage — reserve revision markups for after issuance. Please provide response letter and updated plan set as separate files. Site Engineering Application Review Comments: NOTICE: This is a completeness check review performed by both Site Engineering & Zoning to determine whether the submission in question is sufficient for full review by all applicable reviewing parties. As such, do not interpret the provided comments as finalized complete review comments. They are simply to address outstanding issues caught at this stage of submission. 1. Sheet G0.0 - Sheet Index is missing pages: Sheet numbers differ from Approved plan set (5/20/2026). Please update sheet index on G0.0. 2. Sheet C1.0 – missing detail: The details for new transformer location(s) have not been bubbled, and are stated as being located on Sheet C1.3. There currently does not exist a Sheet C1.3 in this iteration of construction documents. |
||
| 09/03/2026 | CDRC Application Completeness Express | REVIEW COMPLETED | |||
| 09/09/2026 | OK to Submit - Zoning Fast | REVIEW COMPLETED |