Permit Review Detail
Review Status: Requires Resubmit
Review Details: DEVELOPMENT PACKAGE NEW v.1
Permit Number - TD-DEV-1225-00307
Review Name: DEVELOPMENT PACKAGE NEW v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 01/13/2026 | NPPO Standard | NOT REQUIRED | |||
| 01/13/2026 | Site Landscape Standard | NOT REQUIRED | |||
| 12/22/2025 | Site Engineering Standard | REQUIRES RESUBMIT | Permit: TD-DEV-1225-00307 Location: 1845 S CRAYCROFT RD Review Date: 12/22/2025 A Comment Response letter is required. Please address all reviewer’s comments in a separate document with all required documents for resubmittal. Site Engineering Comments: Formatting AM 2-06.4 CONTENT REQUIREMENTS: 1. Provide related and relevant case numbers TD-DEV-1225-00307 & all related permits. (AM 2-06.4.3) 2. The site is affected by recognized City of Tucson Undefined Shallow Flow; change language in Drainage Notes #7: “This project is affected by the City of Tucson Floodplain Regulations.” (AM 2-06.4.7.B.2) 3. Drainage Note #8 and #9 will also change per City of Tucson Floodplain Regulation 4. Streets and roads notes # 10 to be updated to cite Technical Standards Manual 10-01.5.0, not development standard 3-01.0 (AM 2-06.4.7.C.2) 5. Provide missing general note: UTILITIES NOTE (AM 2-06.4.7.D) 6. Provide a Grading Plan with topographical conditions (AM 2-06.4.7.M.1&2) Site Plan Notes Related to Tucson Standards Manual: 7. Show pedestrian circulation to all common use areas; the kiosk area does not connect with the building on the site: “The areas within the development which must be connected include, but are not limited to, all buildings, all bicycle and vehicle parking areas, all recreation areas, all areas, and all other common use areas.” (TSM 7.01-3.B.) 8. Update distance of bollards to match design standard of 4-FT min, 5-FT max (TSM 7-01.4.4.B) Comments Related to Recognized Floodplain: 9. This project/site resides within Naylor-Swan Park Wash Undefined Shallow Flow and will require the submission and approval of a floodplain use (FPU) permit for work within a floodplain. The FPU permit is a separate permit that can be submitted within the "Sub-Records" tab of this associated Development Package (TD-DEV-1225-00307) through TDC-Online. 10. Note, a FPU permit will be needed for each related permit with the development of the site and/or structure. 11. Additionally, an FPU with an Elevation Certificate must be applied for the associated building permit. Apply under “Sub-Records” of TC-FBB-1225-00152. 12. Resubmission with a Grading Plan showing topographical conditions must be provided to determine base flood elevation (BFE). For undefined shallow flow, FFE must be 1-FT above BFE. Additional comments may be forthcoming after addressing reviewers. If you have any questions or concerns, please contact Dylan Molina. Dylan.Molina@tucsonaz.gov |
||
| 01/13/2026 | Site Zoning Standard | REQUIRES RESUBMIT | CDRC TRANSMITTAL FROM: Bobby Parsons PDSD Zoning Review Section PROJECT: New Ice Kiosk – 1845 S. Craycroft Rd. Tucson, AZ 85711 Development Package (1st Review) TD-DEV-1225-00307 TRANSMITTAL DATE: 1/13/2026 DUE DATE: 1/12/2026 COMMENTS: Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed. Section 3.3.3.G.5.c UDC, An applicant has one year from the date of application to obtain approval of a site plan that complies with zoning and other development requirements in effect at the time of application, unless an ordinance adopted by Mayor and Council during this period states otherwise. A site plan application that has been in review for a period of one year and has not yet been approved is considered denied. To continue the review of a site plan for the property, a new site plan must be submitted that complies with regulations in effect at the time of re-submittal. The new submittal initiates a new one-year review period. One year Expiration date is December 18, 2026. SECTION 2-06.0.0: DEVELOPMENT PACKAGE (TENTATIVE PLATS AND SITE PLANS) 2-06.3.0 FORMAT REQUIREMENTS CONTENT REQUIREMENTS 2-06.4.1 - The name, mailing and email addresses, and phone number of the primary property owner of the site, the developer of the project, registrant(s), and other person(s), firm(s), or organization(s) that prepared the development package documents shall be provided on the right half of the cover sheet. The applicable registration or license number shall be provided if prepared by or with the assistance of a registered professional, such as a surveyor, architect, landscape architect, or engineer. All sealing shall be consistent with Arizona Board of Technical Registration guidelines. 1. COMMENT: 2-06.4.1 – Please include the email address and phone number of the owner as noted by the standard above. 2-06.4.2 - The title block shall include the following information and be provided on each sheet: 2-06.4.3 - The administrative street address and relevant case numbers (development package document, subdivision, rezoning, board of adjustment, DDO, MDR, DSMR, overlay, etc.) shall be provided adjacent to the title block on each sheet. 2. COMMENT: 2-06.4.3 - Provide the development package case number, TD-DEV-1225-00307, adjacent to the title block on each sheet. 2-06.4.4.C - Section, township, and range; section corners; north arrow; and the scale will be labeled. 3. COMMENT: 2-06.4.4.C - Please include the section, township, and range; and section corners on your location map as noted by the standard above. 2-06.4.7 - General Notes The following general notes are required. Additional notes specific to each plan are required where applicable. Zoning and Land Use Notes 2-06.4.7.A.4 - Identify the existing and proposed use of the property as classified per the UDC. List all UDC sections applicable to the proposed uses. 4. COMMENT: 2-06.4.7.A.4 - The Use Specific Standards listed are incorrect. For General Merchandise Sales in the C-2 zone, 4.9.9.B.1 is the only Use Specific Standard. 2-06.4.7.A.8 - For development package documents provide: 2-06.4.9 - Information on Proposed Development The following information on the proposed project shall be shown on the drawing or added as notes. 2-06.4.9.F - All existing zoning classifications on and adjacent to the project (including across any adjacent right-of-way) shall be indicated on the drawing with zoning boundaries clearly defined. If the property is being rezoned, use those boundaries and classifications. The basis for this requirement is that some zoning requirements on a project are based on the zoning classification of adjacent property. Also, in some instances, each zone has to be taken into consideration on property that is split by two or more zoning classifications, as each may have different requirements. 5. COMMENT: 2-06.4.9.F – Sheet 2 has C-1 listed as an adjacent zone which is incorrect. This property is surrounded by the C-2 zone to the South, West, North, and R-3 zone to the East. Please remove the reference to the C-1 zone as it is not applicable. 2-06.4.9.H.4 - Indicate if existing streets are public or private; provide street names, widths, curbs, sidewalks, and utility locations, all fully dimensioned. 6. COMMENT: 2-06.4.9.H.4 – Please indicate that both Craycroft Road and 29th Street are “public” as noted by the standard above. 2-06.4.9.R - Show on-site pedestrian circulation and refuge utilizing location and the design criteria in Section 7-01.0.0, Pedestrian Access, of the Technical Standards Manual. 7. COMMENT: 2-06.4.9.R – Please show on-site pedestrian circulation from the kiosk to the existing building as noted by the standard above. 2-06.4.9.T - Show refuse collection areas, including locations of dumpsters, screening location and materials, and vehicle maneuverability, fully dimensioned, and access route. If dumpster service is not proposed, indicate type of service. For specific information on refuse collection, refer to Section 8-01.0.0, Solid Waste and Recycle Disposal, Collection, and Storage, of the Technical Standards Manual. Refuse collection on all projects shall be designed based on that section, even if collection is to be contracted to a private firm. 8. COMMENT: 2-06.4.9.T – Please show the refuse collection area as noted by the standard above. Street view currently shows the trash dumpster encroaching into an existing parking space. ***For additional information on the any standard presented in this memo, please refer to the City of Tucson “Unified Development Code” – Administrative Manual Section 2-06 or Technical Standards noted in the comments. https://www.tucsonaz.gov/pdsd/all-codes-plans-determinations If you have any questions about this transmittal, Contact Bobby Parsons at Robert.Parsons@tucsonaz.gov. RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development package and comment response letter. To resubmit visit Tucson Development Center at https://tdc-online.tucsonaz.gov/#/home. Instructions for resubmittal - https://www.tucsonaz.gov/files/pdsd/website/Resubmittals.pdf. |
||
| 12/19/2025 | CDRC Review Coordinator Express | REVIEW COMPLETED | CDRC added TEP, PAG, USPS, and SWG to the workflow. Review request email sent to TEP. FYI email sent to PAG, USPS, SWG. | ||
| 01/12/2026 | Commercial Plumbing Standard | REVIEW COMPLETED | |||
| 12/19/2025 | External Reviewers - Pima Association of Governments Standard | REVIEW COMPLETED | CDRC sent FYI email sent to PAG, USPS, SWG. No further action is required. | ||
| 12/19/2025 | External Reviewers - Southwest Gas Standard | REVIEW COMPLETED | CDRC sent FYI email sent to PAG, USPS, SWG. No further action is required. | ||
| 01/09/2026 | External Reviewers - Tucson Electric Power (TEP) Standard | REVIEW COMPLETED | 4350 E. Irvington Road Post Office Box 711, Tucson, AZ 85702 January 8, 2026 WO#T172420 City of Tucson Planning and Development Services Attn: CDRC Admin Team Dear CDRC Admin Team Subject: New Ice Kisok replacing old TD-DEV-1225-00307 Tucson Electric Power Company (TEP) has reviewed and approved the development plan submitted 12/19/2025. There are existing facilities within the development which are depicted upon the plan. POSSIBLE CONFLICTS WITH OVERHEAD POLE LINE IN THE ALLEY, UNDERGROUND SECONDARY ON LOT (NOT CALLED OUT ON DP), AND SUBSURFACE JUNCTION BOX ON LOT (NOT CALLED OUT ON DP). PLEASE CONTACT TEP DESIGN IF RELOCATION IS REQUIRED Enclosed is a copy of a TEP facilities map showing the approximate location of the existing facilities. Any relocation costs will be billable to the customer. To apply for electric service, please call the New Construction department at (520) 918- 8300. Please submit a final set of plans including approved site, electric load, paving off-site improvements and irrigation plans. If available, include a PDF version of the plans. If easements are required, they will be secured by separate instrument. Should you have any easement questions, please contact our Land Resources Department, LandReviews@tep.com. Should you have any technical questions, please contact the area designer, Martin Salazar (520) 305-6713 msalazar@tep.com Sincerely, Design Admins Design Admins Tucson Electric Power |
||
| 12/19/2025 | External Reviewers - United States Postal Service (USPS) Standard | REVIEW COMPLETED | CDRC sent FYI email sent to PAG, USPS, SWG. No further action is required. | ||
| 01/12/2026 | Fire New Construction Standard | REVIEW COMPLETED | |||
| 12/16/2025 | OK to Submit - Engineering Fast | REVIEW COMPLETED | |||
| 12/18/2025 | OK to Submit - Zoning Fast | REVIEW COMPLETED | |||
| 01/07/2026 | ROW Engineering Review Standard | REVIEW COMPLETED | DTM Comments- No improvements within Right of Way required. Any work Performed within DTM row to require separate and individual permit submissions at the time of work.. |