Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: TD-DEV-1225-00299
Parcel: 131050040

Address:
5438 E 29TH ST

Review Status: Requires Resubmit

Review Details: DEVELOPMENT PACKAGE NEW v.2

Permit Number - TD-DEV-1225-00299
Review Name: DEVELOPMENT PACKAGE NEW v.2
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
07/02/2026 Site Zoning Standard APPROVED
06/22/2026 External Reviewers - Tucson Electric Power (TEP) Standard REQUIRES RESUBMIT June 18, 2026
WO#T185822
City of Tucson
Planning and Development Services
Attn: CDRC Admin Team
Dear CDRC Admin Team
Subject: L5 Security Fencing and Gates
TD-DEV-1225-00299
Tucson Electric Power Company (TEP) has reviewed and cannot approve the
development plan submitted 6/3/2026. There are existing facilities within the
development which are not depicted upon the plan. No apparent conflict with fence
installation. Please contact TEP design if equipment relocation is necessary. Further:
Development plan does not show 10' Public Utility Easement as granted in Ferry
Addition Bk 09 Pg 5 subdivision plat
Enclosed is a copy of a TEP facilities map showing the approximate location of the
existing facilities. Any relocation costs will be billable to the customer.
To apply for electric service, please call the New Construction department at (520) 918-
8300. Please submit a final set of plans including approved site, electric load, paving
off-site improvements and irrigation plans. If available, include a PDF version of the
plans.
Questions regarding Land, ROW, Easement, etc., please contact the TEP Land
Department
Liz Boehler
Right of Way Agent
Consultant
520-686-1341
Landreviews@tep.com
Should you have any technical questions, please contact the area designer,
Martin Salazar
(520) 305-6713
msalazar@tep.com
Sincerely,
Design Admins
Design Admins
Tucson Electric Power
06/20/2026 Fire New Construction Standard REQUIRES RESUBMIT -Provide Knox box at all gates for fire dept. access. Add note to drawings.
john.vincent@tucsonaz.gov
5203495581
06/15/2026 ROW Engineering Review Standard REQUIRES RESUBMIT Gated entrances shall be allowed for commercial/industrial developments and shall meet the following requirements:
Stopping locations for keypads, card-readers, guard shacks, etc. shall be set back from the right-of-way of the cross street to avoid interfering with through traffic.
The gate may not encroach into the travel lane when open.
Any equipment or obstructions such as keypads or card-readers shall be installed in a median island.
06/03/2026 Site Engineering Standard REQUIRES RESUBMIT Permit Activity Number: TD-DEV-1225-00299 (1st Review)
Project: Submitting Minor DP to document unpermitted security fencing and gates
Location: 5438 E 29TH ST
Review Date: 6/3/2026
Reviewer: Marco Contreras – Engineering Associate
Reviewer Contact Information: marco.contreras@tucsonaz.gov
Related cases:

Plan review for the above-referenced development package has been completed. This review was conducted for compliance with applicable development criteria including the City of Tucson Unified Development Code (UDC), Administrative Manual (AM) Section 2-6, and Technical Standards Manual (TSM) sections governing waste management, pedestrian access, hydrology – retention/detention requirements, and all applicable site standards.
The following comments must be addressed prior to approval. To help facilitate a timely resubmittal, please provide updated plans and calculations along with a written response to each comment, indicating what action was taken and where the change can be found on the plans. Do not use revision clouds on resubmittal drawings — clouds are reserved for post-permit revisions only. Submit your response letter and updated plan set & reports as separate files.
Applicable Code Links for quick/direct reference:
City of Tucson Code: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Codes
Floodplain Code: https://codelibrary.amlegal.com/codes/tucson/latest/tucson_az/0-0-0-19333
Drainage Manual Link: https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/engineering-code/cot-drainage-manual-searchable.pdf
Design standards for Stormwater Detention and Retention Link:
https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/engineering-code/updated-retention-detention-manual.pdf

Site Engineering Review Comments:
1. Provide a general note that states - Accessible standards must be met per 2024 IBC, chapter 11, and 2017 ICC A117.1
2. Ensure to delineate the required clearance is 14x40 feet with a required height clearance of 25ft. TSM 8-01.0.0. Please show this required space delineated for the trash enclosure.
3. After review of the plan set provided, it appears it does not meet the minimum standards as established in TSM 8-01.5.3 Access standards
a. Environmental services approval will be required in regard to accepting that they will have no issues in regard to servicing the trash dumpster behind keyed access. The contact to reach out to at ES will be Andy Vera at Andy.vera@tucsonaz.gov. Please submit the approval provided for the resubmission of this development package.
4. Provide construction details for all pedestrian gates that demonstrate compliance with 2010 ADA standards with ICC A117.1 – 2017. This includes, but is not limited to:
a. Compliant maneuvering clearance must be provided on both sides of the gate, per the applicable table based on gate type and approach direction
b. Ground/floor surface within maneuvering clearance must be level (max 1:48 slope in any direction)
c. Hardware specifications 404.2.7
d. Thresholds 404.2.5
05/28/2026 CDRC Application Completeness Express REVIEW COMPLETED
06/02/2026 CDRC Review Coordinator Express REVIEW COMPLETED CDRC added Addressing, PAG, USPS, and SWG to the workflow. Review request email sent to Addressing.  FYI email sent to PAG, USPS, SWG.
06/02/2026 External Reviewers - Pima Association of Governments Standard REVIEW COMPLETED CDRC sent FYI email sent to PAG, USPS, SWG. No further action is required.
06/04/2026 External Reviewers - Pima County Addressing Standard REVIEW COMPLETED ​CDRC​
Good morning,

TD-DEV-1225-00299 does not require review from Pima County Addressing.

Thank you,







David Wilging

Planner I - Addressing Division

Pima County Development Services

201 N. Stone Avenue 1st Floor

Tucson, Arizona 85701

520-724-6381
06/02/2026 External Reviewers - Southwest Gas Standard REVIEW COMPLETED CDRC sent FYI email sent to PAG, USPS, SWG. No further action is required.
06/02/2026 External Reviewers - United States Postal Service (USPS) Standard REVIEW COMPLETED CDRC sent FYI email sent to PAG, USPS, SWG. No further action is required.
05/29/2026 OK to Submit - Zoning Fast REVIEW COMPLETED