| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 06/04/2024 | CDRC Post Review Express | PENDING ASSIGNMENT | |||
| 06/03/2024 | Commercial Plumbing | REQUIRES RESUBMIT | The rim elevations of the proposed new manholes (2309.7’) are higher than the FFE (2308.75’). Provide a backwater valve per Section 714.1, IPC 2018, as amended by the City of Tucson. [Comment not resolved. Verify that you will be allowed to locate a building sewer in the right of way. Show the proposed pipe sizes. The construction of a building sewer that includes manholes will require a review of the system design by the Pima County Department of Environmental Quality as well as a building permit from the City of Tucson. Reference Title 18, R18-9-E302, 4.02 General Permit, Arizona Administrative Code.] [Initial comment: Revise the site drawing to include the invert and rim elevations of the manholes upstream and downstream of the connection to the public sewer. Include the Pima County Wastewater Management Department (PCWMD) reference number. Reference: City of Tucson Administrative Manual, Section 2-06.4.8D and Section 107.2.1, IBC 2018.] | ||
| 05/01/2024 | External Reviewers - Arizona Department of Transportation (ADOT) | REQUIRES RESUBMIT | ADOT (Permits) is currently working with the Developer to finalize comments on the Site Plans. The Developer (Atwell) has requested to update their status. Let us know if you have any questions or concerns. |
||
| 05/16/2024 | External Reviewers - COT Environmental Services | REQUIRES RESUBMIT | ES comments as follows: 1. TSM 8-01.5.3.B, A minimum safe access and operational area of fourteen (14) feet by forty (40) feet, with a minimum vertical clearance of twenty-five (25) feet, shall be provided in front of each enclosure. Depict 14’x40’ clear approach in front of enclosure within drawing detail and identify. This area should have a 3ft clear between any structure. Include turning radii, 50ft outside and 36ft inside. 2. Trash enclosure notes on page 2 of DP IS note sufficient. Items I & J are not applicable. Must provide enclosure wall construction detail with all dimensions called out. Refer to TSM 8-01.9.0 Figures 2 & 3B. 3. DP page 2, identifies two different enclosure options. Remove 13-B as this option is not shown on the site plan as 13-A was the version within the drawing. Or clarify the intent. Please contact me if you have any questions regarding this review. Andy Vrea (520) 837-3798 Andy.Vera@tucsonaz.gov |
||
| 05/30/2024 | Site Engineering | REQUIRES RESUBMIT | 1. The Conditions, Covenants, and Restrictions for the proposed underground storage system must be submitted prior to the approval of the plans. They will be sent by PDSD to the Floodplain Administrator for approval. Please provide the CC&Rs. Lianne Evans lianne.evans@tucsonaz.gov |
||
| 06/04/2024 | Site Landscape | REQUIRES RESUBMIT | CDRC TRANSMITTAL PLANNING AND DEVELOPMENT SERVICES DEPARTMENT REVIEWER: CHAD KELLER, RLA PDSD SITE LANDSCAPE/NATIVE PLANT PRESERVATION SECTION PROJECT: NEW MISTER CAR WASH BUILDING ACTIVITY NO: TD-DEV-1223-00492 ADDRESS/PARCEL: 4646 N ORACLE RD/105110490 ZONING: C-3 COMMERCIAL ZONE This plan has been reviewed for compliance with applicable development criteria in the City of Tucson Unified Development Code (UDC) Administrative Manual (AM) Section 2-11 and Technical Manual (TM) Section for landscape, native plants, and water harvesting. Please resubmit revised drawings along with a detailed response letter, which states how all Landscape/NPPO Review Section comments are addressed. COMMENTS: 1. Ensure that Engineering comments and concerns are addressed prior to landscape section approval. 2. Label the property lines on all landscape sheets. 3. Label the irrigation meter as “irrigation only” on the irrigation plan and on the irrigation schedule. See TSM 4-01.6.0 4. Planting and irrigation appear to be in the ROW along N Oracle Rd. Any landscape being proposed in the ROW must be approved by DTM. Please contact David Marhefka (david.marhefka@tucsonaz.gov) for review and approval. 5. Include a construction detail showing root barriers for trees located near hardscape areas. (see Detail 402 located here: https://www.tucsonaz.gov/Departments/Transportation-Mobility/Landscape/Landscape-Architects If you have any questions about these comments, I can be reached at chad.keller@tucsonaz.gov |
||